The utilities comprise of useful IOC db templates and IOC shell utilities.
Below are available utility templates for substitution. In order to allow Make to build these, you need to add the following to your Device/master/configure/RELEASE
file: UTILITIES=$(SUPPORT)/utilities/master
.
This copies the specified field from a PV and sets it on a different PV. E.g.
file $(UTILITIES)/db/field_setter.template {
pattern
{P, FROM, TO, FIELD}
{"\$(P)", "UNITS", "READING", "EGU"}
{"\$(P)", "UNITS", "SP", "EGU"}
}
This example copies the EGU
field from $(P)READING
to $(P)UNITS.EGU
and $(P)SP.EGU
.
This copies units from a PV and sets them on a different PV. E.g.
file $(UTILITIES)/db/unit_setter.template {
pattern
{P, FROM, TO}
{"\$(P)", "UNITS", "READING"}
{"\$(P)", "UNITS", "SP"}
}
This will copy units from the value of the PV $(P)UNITS
to $(P)READING
and $(P)SP
.
Creates a raw PV that can be written to by a stream protocol and then transfer the stream protocols PV error and value to the real PV.
For example:
file $(UTILITIES)/db/error_setter.template {
pattern {P, STREAM_PV, PV_NAME}
{"\$(P)", "FREQ:REF", "FREQ:SP:RBV"}
{"\$(P)", "FREQ:REF", "FREQ"}
}
In this example, the PV FREQ:REF
reads the values from a status and then set the values, via the protocol file, in the FREQ:SP:RBV:RAW.A
PV. This value and any error that occurs in the FREQ:REF
is then set on the FREQ:SP:RBV
PV. This allows you to easily show a disconnected error in PVs that are set from the protocol file.
If you need to use the error setter for PVs that are defined in a .db file instead of .template file, the .substitutions file for that .db file needs to have a different name than the .db file, otherwise the error setter will not work.
Calculates the maximum and minimum values of a selected calibration file. You can load this db with macros using
dbLoadRecords("$(UTILITIES)/db/calibration_range.db","P=$(P),BDIR=TEMP.BDIR,TDIR=TEMP.TDIR,SPEC=TEMP.SPEC,HIGH_PV=TEMP:RANGE:OVER.B,LOW_PV=TEMP:RANGE:UNDER.B")
Where TEMP
is a cvt
record which uses the calibration file. The max value is outputted to HIGH_PV
and the minimum to LOW_PV
.
There are some IOC shell utilities defined in C:\Instrument\Apps\EPICS\support\utilities
which can be used in an IOC shell to help startup IOCs. The doxygen docs are here http://epics.isis.rl.ac.uk/doxygen/main/support/utilities/.
You can pause an IOC at startup in the st.cmd using msgBox
. This is imported in IOC_NAME_registerRecordDeviceDriver pdbbase
so must come after that line. Usage: msgBox "title" "text"
Which will bring up a message box at the point in your startup that it is placed and pause the boot until you click the button.
This could be useful if you want to run a debugger on the IOC, which you attach whilst the IOC boot is paused.
Performs an arithmetic operation on an expression and return the integer value to a specific environment variable:
calc("ENV1","1+1",1,2)
The arguments are as follows:
- The output environment variable
- The expression to be evaluated
- Options
- The output length
My best guess is that the expression is evaluated using the calcPerform
method from the EPICS standard library so the expression should match the syntax as used in a calc record.
The options are detailed in ioccalc.cpp
in the utilities directory.
Examples can be seen in the Galil and McLennan motor records.
As calc, but returns a double value. The 4th argument is for the number of decimal places, not the value length.
dcalc("ENV1","0.1*0.2",1,2)
An example can be seen in the Eurotherm IOC, file st-timing.cmd
.
TODO
Defines an environment variables as empty or a comment depending on if lhs is empty. The variables defined are:
-
IF<resultsvar>
'#' if empty; otherwise ' ' -
IFNOT<resultsvar>
' ' if empty; otherwise '#'
parameters
-
resultvar
- the basename of the environment variable to set -
lhs
- the string to test -
operation
- set the first bit for verbose mode -
rhs
- does nothing
The operation argument is given as a decimal representation of binary flags:
Operation | Flag |
---|---|
Verbose | 0x1 |
length > 0 | 0x2 |
lhs == rhs | 0x4 |
Inverse output | 0x8 |
To get the operation that you require, add the flag value in decimal. For example, to check if a string has finite length, your operation would be 2
. However, if you would like your flag to check if a string has a zero length, then add the inverse flag value 8
, meaning your operation would be 10 (8+2)
. To add a log for this operation, add the verbose flag of value 1
, so the total value is 11
.
For debugging purposes it is advisable to add the verbose/logging flag of value 1
to your operation.
From the DKFPS IOC:
stringiftest("POLAR" "$(POLARITY="BIPOLAR")" 5 "BIPOLAR")
The operation value is 5
, or 4+1
, so this checks the lhs ($(POLARITY)
, which defaults to "BIPOLAR"
) equals the right hand side "BIPOLAR"
, and puts the result in the $(POLAR)
.