This is an example on how to configure the mqtt sensors in Home Assistant:
<snip>
# Deye Sun 600G3-EU-230 MQTT Sensor definition
mqtt:
sensor:
- name: "deye_ac_active_power"
unique_id: "deye_ac_active_power"
device_class: "power"
state_topic: "deye/ac/ac_active_power"
unit_of_measurement: "W"
- name: "deye_ac_l1_power"
unique_id: "deye_ac_l1_power"
device_class: "power"
state_topic: "deye/ac/l1_power"
unit_of_measurement: "W"
- name: "deye_ac_l1_current"
unique_id: "deye_ac_l1_current"
device_class: "current"
state_topic: "deye/ac/l1_current"
unit_of_measurement: "A"
- name: "deye_ac_l1_voltage"
unique_id: "deye_ac_l1_voltage"
device_class: "voltage"
state_topic: "deye/ac/l1_voltage"
unit_of_measurement: "V"
- name: "deye_ac_freq"
unique_id: "deye_ac_freq"
device_class: "frequency"
state_topic: "deye/ac/ac_freq"
unit_of_measurement: "Hz"
- name: "deye_dc_pv1_power"
unique_id: "deye_dc_pv1_power"
device_class: "power"
state_topic: "deye/dc/pv1_power"
unit_of_measurement: "W"
- name: "deye_dc_pv1_current"
unique_id: "deye_dc_pv1_current"
device_class: "current"
state_topic: "deye/dc/pv1_current"
unit_of_measurement: "A"
- name: "deye_dc_pv1_voltage"
unique_id: "deye_dc_pv1_voltage"
device_class: "voltage"
state_topic: "deye/dc/pv1_voltage"
unit_of_measurement: "V"
- name: "deye_dc_pv2_power"
unique_id: "deye_dc_pv2_power"
device_class: "power"
state_topic: "deye/dc/pv2_power"
unit_of_measurement: "W"
- name: "deye_dc_pv2_current"
unique_id: "deye_dc_pv2_current"
device_class: "current"
state_topic: "deye/dc/pv2_current"
unit_of_measurement: "A"
- name: "deye_dc_pv2_voltage"
unique_id: "deye_dc_pv2_voltage"
device_class: "voltage"
state_topic: "deye/dc/pv2_voltage"
unit_of_measurement: "V"
- name: "deye_dc_total_power"
unique_id: "deye_dc_total_power"
device_class: "power"
state_topic: "deye/dc/dc_total_power"
unit_of_measurement: "W"
- name: "deye_total_energy"
unique_id: "deye_total_energy"
device_class: "energy"
state_topic: "deye/total_energy"
unit_of_measurement: "kWh"
- name: "deye_radiator_temp"
unique_id: "deye_radiator_temp"
device_class: "temperature"
state_topic: "deye/radiator_temp"
unit_of_measurement: "°C"
- name: "deye_esp_mem_free"
unique_id: "deye_esp_mem_free"
device_class: "data_size"
state_topic: "deye/esp_mem_free"
unit_of_measurement: "B"
- name: "deye_esp_os_resetcause"
unique_id: "deye_esp_os_resetcause"
state_topic: "deye/esp_os_resetcause"
</snip>