diff --git a/docs/source/workflow_inputs.rst b/docs/source/workflow_inputs.rst index 8f88c79bfd..47b6b924bd 100644 --- a/docs/source/workflow_inputs.rst +++ b/docs/source/workflow_inputs.rst @@ -1967,9 +1967,12 @@ If a mini-split heat pump is specified, additional information is entered in ``H HeatingDetailedPerformanceData must also be provided. .. [#] If HeatingDetailedPerformanceData is provided, see :ref:`htg_detailed_perf_data`. CoolingDetailedPerformanceData must also be provided. - .. [#] | If neither extension/HeatingCapacityRetention nor HeatingCapacity17F nor HeatingDetailedPerformanceData provided, heating capacity retention defaults based on CompressorType: - | - **single/two stage**: 0.425 (at 5F) - | - **variable speed**: 0.0461 * HSPF + 0.1594 (at 5F) + .. [#] If neither extension/HeatingCapacityRetention nor HeatingCapacity17F nor HeatingDetailedPerformanceData provided, heating capacity retention defaults based on CompressorType: + + \- **single/two stage**: 0.425 (at 5F) + + \- **variable speed**: 0.0461 * HSPF + 0.1594 (at 5F) + .. [#] The extension/HeatingCapacityRetention input is a more flexible alternative to HeatingCapacity17F, as it can apply to autosized systems and allows the heating capacity retention to be defined at a user-specified temperature (instead of 17F). Either input approach can be used, but not both. .. [#] FanPowerWattsPerCFM defaults to 0.07 W/cfm for ductless systems and 0.18 W/cfm for ducted systems.