Manta Deployment

(Up to the Manta Operator Guide front page.)

This section describes how to plan for and deploy a new Manta.

Contents

Planning a Manta deployment

Before even starting to deploy Manta, you must decide:

  • the number of datacenters
  • the number of metadata shards
  • the number of storage and non-storage compute nodes
  • how to lay out the non-storage zones across the fleet

Choosing the number of datacenters

You can deploy Manta across any odd number of datacenters in the same region (i.e., having a reliable low-latency, high-bandwidth network connection among all datacenters). We've only tested one- and three-datacenter configurations. Even-numbered configurations are not supported. See "Other configurations" below for details.

A single-datacenter installation can be made to survive server failure, but obviously cannot survive datacenter failure. The us-east deployment uses three datacenters.

Choosing the number of metadata shards

Recall that each metadata shard has the storage and load capacity of a single postgres instance. If you want more capacity than that, you need more shards. Shards can be added later without downtime, but it's a delicate operation. The us-east deployment uses three metadata shards, plus a separate shard for the compute and storage capacity data.

We recommend at least two shards so that the compute and storage capacity information can be fully separated from the remaining shards, which would be used for metadata.

Choosing the number of storage and non-storage compute nodes

The two classes of node (storage nodes and non-storage nodes) usually have different hardware configurations.

The number of storage nodes needed is a function of the expected data footprint and (secondarily) the desired compute capacity.

The number of non-storage nodes required is a function of the expected load on the metadata tier. Since the point of shards is to distribute load, each shard's postgres instance should be on a separate compute node. So you want at least as many compute nodes as you will have shards. The us-east deployment distributes the other services on those same compute nodes.

For information on the latest recommended production hardware, see Joyent Manufacturing Matrix and Joyent Manufacturing Bill of Materials.

The us-east deployment uses older versions of the Tenderloin-A for service nodes and Mantis Shrimps for storage nodes.

Choosing how to lay out zones

Since there are so many different Manta components, and they're all deployed redundantly, there are a lot of different pieces to think about. (The production deployment in us-east has 20+ zones in each of the three datacenters.) So when setting up a Manta deployment, it's very important to think ahead of time about which components will run where!

The manta-adm genconfig tool (when used with the --from-file option) can be very helpful in laying out zones for Manta. See the manta-adm manual page for details. manta-adm genconfig --from-file takes as input a list of physical servers and information about each one. Large deployments that use Device 42 to manage hardware inventory may find the manta-genazconfig tool useful for constructing the input for manta-adm genconfig.

The most important production configurations are described below, but for reference, here are the principles to keep in mind:

  • Storage zones should only be located in dedicated storage nodes. We do not recommend co-locating them with other services. All other zones should be deployed onto non-storage compute nodes.
  • Nameservice: There must be an odd number of "nameservice" zones in order to achieve consensus, and there should be at least three of them to avoid a single point of failure. There must be at least one in each DC to survive any combination of datacenter partitions, and it's recommended that they be balanced across DCs as much as possible.
  • For the non-sharded, non-ops-related zones (which is everything except moray, postgres, ops, madtom), there should be at least two of each kind of zone in the entire deployment (for availability), and they should not be in the same datacenter (in order to survive a datacenter loss). For single-datacenter deployments, they should at least be on separate compute nodes.
  • Only one madtom zone is considered required. It would be good to provide more than one in separate datacenters (or at least separate compute nodes) for maintaining availability in the face of a datacenter failure.
  • There should only be one ops zone. If it's unavailable for any reason, that will only temporarily affect metering, garbage collection, and reports.
  • For postgres, there should be at least three instances in each shard. For multi-datacenter configurations, these instances should reside in different datacenters. For single-datacenter configurations, they should be on different compute nodes. (Postgres instances from different shards can be on the same compute node, though for performance reasons it would be better to avoid that.)
  • For moray, there should be at least two instances per shard in the entire deployment, and these instances should reside on separate compute nodes (and preferably separate datacenters).
  • garbage-collector zones should not be configured to poll more than 6 shards. Further, they should not be co-located with instances of other CPU-intensive Manta components (e.g. loadbalancer) to avoid interference with the data path.

Most of these constraints are required in order to maintain availability in the event of failure of any component, server, or datacenter. Below are some example configurations.

Example single-datacenter, multi-server configuration

On each storage node, you should deploy one "storage" zone.

If you have N metadata shards, and assuming you'll be deploying 3 postgres instances in each shard, you'd ideally want to spread these over 3N compute nodes. If you combine instances from multiple shards on the same host, you'll defeat the point of splitting those into shards. If you combine instances from the same shard on the same host, you'll defeat the point of using replication for improved availability.

You should deploy at least two Moray instances for each shard onto separate compute nodes. The remaining services can be spread over the compute nodes in whatever way, as long as you avoid putting two of the same thing onto the same compute node. Here's an example with two shards using six compute nodes:

CN1 CN2 CN3 CN4 CN5 CN6
postgres 1 postgres 1 postgres 1 postgres 2 postgres 2 postgres 2
moray 1 moray 1 electric-moray moray 2 moray 2 electric-moray
nameservice webapi nameservice webapi nameservice webapi
ops madtom garbage-collector loadbalancer loadbalancer loadbalancer
storinfo authcache storinfo authcache

In this notation, "postgres 1" and "moray 1" refer to an instance of "postgres" or "moray" for shard 1.

Example three-datacenter configuration

All three datacenters should be in the same region, meaning that they share a reliable, low-latency, high-bandwidth network connection.

On each storage node, you should deploy one "storage" zone.

As with the single-datacenter configuration, you'll want to spread the postgres instances for N shards across 3N compute nodes, but you'll also want to deploy at least one postgres instance in each datacenter. For four shards, we recommend the following in each datacenter:

CN1 CN2 CN3 CN4
postgres 1 postgres 2 postgres 3 postgres 4
moray 1 moray 2 moray 3 moray 4
nameservice nameservice electric-moray authcache
webapi webapi loadbalancer loadbalancer
ops garbage-collector madtom storinfo

In this notation, "postgres 1" and "moray 1" refer to an instance of "postgres" or "moray" for shard 1.

Other configurations

For testing purposes, it's fine to deploy all of Manta on a single system. Obviously it won't survive server failure. This is not supported for a production deployment.

It's not supported to run Manta in an even number of datacenters since there would be no way to maintain availability in the face of an even split. More specifically:

  • A two-datacenter configuration is possible but cannot survive datacenter failure or partitioning. That's because the metadata tier would require synchronous replication across two datacenters, which cannot be maintained in the face of any datacenter failure or partition. If we relax the synchronous replication constraint, then data would be lost in the event of a datacenter failure, and we'd also have no way to resolve the split-brain problem where both datacenters accept conflicting writes after the partition.
  • For even numbers N >= 4, we could theoretically survive datacenter failure, but any N/2 -- N/2 split would be unresolvable. You'd likely be better off dividing the same hardware into N - 1 datacenters.

It's not supported to run Manta across multiple datacenters not in the same region (i.e., not having a reliable, low-latency, high-bandwidth connection between all pairs of datacenters).

Deploying Manta

Before you get started for anything other than a COAL or lab deployment, be sure to read and fully understand the section on "Planning a Manta deployment" above.

A note on channel support

The two main commands used to deploy and maintain Manta, manta-init and manta-adm operate on software delivered as Triton images. These images are retrieved from https://updates.tritondatacenter.com by default. Both manta-init and manta-adm are "channel aware", taking -C options to override the Triton image channel to download images from. The default channel for a Manta deployment can be set using sdcadm channel set ... within a given datacenter.

Step by step instructions

These general instructions should work for anything from COAL to a multi-DC, multi-compute-node deployment. The general process is:

  1. Set up Triton in each datacenter, including the headnode, all Triton services, and all compute nodes you intend to use. For easier management of hosts, we recommend that the hostname reflect the type of server and, possibly, the intended purpose of the host. For example, we use the "RA" or "RM" prefix for "Richmond-A" hosts and "MS" prefix for "Mantis Shrimp" hosts.

  2. In the global zone of each Triton headnode, set up a manta deployment zone using:

     sdcadm post-setup common-external-nics  # enable downloading service images
     sdcadm post-setup manta
    
  3. In each datacenter, generate a Manta networking configuration file.

    a. For COAL, from the GZ, use:

     headnode$ /zones/$(vmadm lookup alias=manta0)/root/opt/smartdc/manta-deployment/networking/gen-coal.sh > /var/tmp/netconfig.json
    

    b. For those using the internal Joyent Engineering lab, run this from the lab.git repo:

     lab.git$ node bin/genmanta.js -r RIG_NAME LAB_NAME
    
    and copy that to the headnode GZ.
    

    c. For other deployments, see "Networking configuration" below.

  4. Once you've got the networking configuration file, configure networks by running this in the global zone of each Triton headnode:

     headnode$ ln -s /zones/$(vmadm lookup alias=manta0)/root/opt/smartdc/manta-deployment/networking /var/tmp/networking
     headnode$ cd /var/tmp/networking
     headnode$ ./manta-net.sh CONFIG_FILE
    

    This step is idempotent. Note that if you are setting up a multi-DC Manta, ensure that (1) your Triton networks have cross datacenter connectivity and routing set up and (2) the Triton firewalls allow TCP and UDP traffic cross- datacenter.

  5. For multi-datacenter deployments, you must link the datacenters within Triton so that the UFDS database is replicated across all three datacenters.

  6. For multi-datacenter deployments, you must configure SAPI for multi-datacenter support.

  7. If you'll be deploying a loadbalancer on any compute nodes other than a headnode, then you'll need to create the "external" NIC tag on those CNs. For common single-system configurations (for dev and test systems), you don't usually need to do anything for this step. For multi-CN configurations, you probably will need to do this. See the Triton documentation for how to add a NIC tag to a CN.

  8. In each datacenter's manta deployment zone, run the following:

     manta$ manta-init -s SIZE -e YOUR_EMAIL
    

    manta-init must not be run concurrently in multiple datacenters.

    SIZE must be one of "coal", "lab", or "production". YOUR_EMAIL is used to create an Amon contact for alarm notifications.

    This step runs various initialization steps, including downloading all of the zone images required to deploy Manta. This can take a while the first time you run it, so you may want to run it in a screen session. It's idempotent.

  9. In each datacenter's manta deployment zone, deploy Manta components.

    a. In COAL, just run manta-deploy-coal. This step is idempotent.

    b. For a lab machine, just run manta-deploy-lab. This step is idempotent.

    c. For any other installation (including a multi-CN installation), you'll need to run several more steps: assign shards for storage and object metadata with "manta-shardadm"; create a hash ring with "manta-adm create-topology"; generate a "manta-adm" configuration file (see "manta-adm configuration" below); and finally run "manta-adm update config.json" to deploy those zones. Your best bet is to examine the "manta-deploy-dev" script to see how it uses these tools. See "manta-adm configuration" below for details on the input file to "manta-adm update". Each of these steps is idempotent, but the shard and hash ring must be set up before deploying any zones.

  10. If desired, set up connectivity to the "ops" and "madtom" zones. See "Overview of Operating Manta" below for details.

  11. For multi-datacenter deployments, set the MUSKIE_MULTI_DC SAPI property. This is required to enforce that object writes are distributed to multiple datacenters. In the SAPI master datacenter:

    headnode $ app_uuid="$(sdc-sapi /applications?name=manta | json -Ha uuid)"
    headnode $ echo '{ "metadata": { "MUSKIE_MULTI_DC": true } }' | \
        sapiadm update "$app_uuid"
    

    Repeat the following in each datacenter.

    headnode $ manta-oneach -s webapi 'svcadm restart "*muskie*"'
    
  12. If you wish to enable basic monitoring, run the following in each datacenter:

    manta-adm alarm config update
    

    to deploy Amon probes and probe groups shipped with Manta. This will cause alarms to be opened when parts of Manta are not functioning. Email notifications are enabled by default using the address provided to manta-init above. (Email notifications only work after you have configured the Amon service for sending email.) If you want to be notified about alarm events via XMPP, see "Changing alarm contact methods" below.

  13. In development environments with more than one storage zone on a single system, it may be useful to apply quotas to storage zones so that if the system fills up, there remains space in the storage pool to address the problem. You can do this by finding the total size of the storage pool using zfs list zones in the global zone:

    # zfs list zones
    NAME    USED  AVAIL  REFER  MOUNTPOINT
    zones  77.5G   395G   612K  /zones
    

    Determine how much you want to allow the storage zones to use. In this case, we'll allow the zones to use 100 GiB each, making up 300 GiB, or 75% of the available storage. Now, find the storage zones:

    # manta-adm show storage
    SERVICE          SH ZONENAME                             GZ ADMIN IP
    storage           1 15711409-ca77-4204-b733-1058f14997c1 172.25.10.4
    storage           1 275dd052-5592-45aa-a371-5cd749dba3b1 172.25.10.4
    storage           1 b6d2c71f-ec3d-497f-8b0e-25f970cb2078 172.25.10.4
    

    and for each one, update the quota using vmadm update. You can apply a 100 GiB quota to all of the storage zones on a single-system Manta using:

    manta-adm show -H -o zonename storage | while read zonename; do
        vmadm update $zonename quota=100; done
    

    Note: This only prevents Manta storage zones from using more disk space than you've budgeted for them. If the rest of the system uses more than expected, you could still run out of disk space. To avoid this, make sure that all zones have quotas and the sum of quotas does not exceed the space available on the system.

    Background: Manta operators are responsible for basic monitoring of components, including monitoring disk usage to avoid components running out of disk space. Out of the box, Manta stops using storage zones that are nearly full. This mechanism relies on storage zones reporting how full they are, which they determine by dividing used space by available space. However, Manta storage zones are typically deployed without quotas, which means their available space is limited by the total space in the ZFS storage pool. This accounting is not correct when there are multiple storage zones on the same system.

    To make this concrete, consider a system with 400 GiB of total ZFS pool space. Suppose there are three storage zones, each using 100 GiB of space, and suppose that the rest of the system uses negligible storage space. In this case, there are 300 GiB in use overall, so there's 100 GiB available in the pool. As a result, each zone reports that it's using 100 GiB and has 100 GiB available, so it's 50% full. In reality, though, the system is 75% full. Each zone reports that it has 100 GiB free, but if we were to write just 33 GiB to each zone, the whole system would be full.

    This problem only affects deployments that place multiple storage zones on the same system, which is not typical outside of development. In development, the problem can be worked around by applying appropriate quotas in each zone (as described above).

Post-Deployment Steps

Once the above steps have been completed, there are a few steps you should consider doing to ensure a working deployment.

Prerequisites

If you haven't already done so, you will need to install the Manta CLI tools.

Set up a Manta Account

To test Manta with the Manta CLI tools, you will need an account configured in Triton. You can either use one of the default configured accounts or setup your own. The most common method is to test using the poseidon account which is created by the Manta install.

In either case, you will need access to the Operations Portal. See the instructions here on how to find the IP address of the Operations Portal from your headnode.

Log into the Operations Portal:

  • COAL users should use login admin and the password you initially setup.
  • Lab users will also use admin, but need to ask whoever provisioned your lab account for the password.

Once in, follow these instructions to add ssh keys to the account of your choice.

Test Manta from the CLI Tools

Once you have setup an account on Manta or added your ssh keys added to an existing account, you can test your Manta install with the Manta CLI tools you installed above in "Prerequisites".

There are complete instructions on how to get started with the CLI tools in the User Guide.

Some things in that guide will not be as clear for users of custom deployments.

  1. The biggest difference will be the setting of the MANTA_URL variable. You will need to find the IP address of your API endpoint. To do this from your headnode:

     headnode$ manta-adm show -H -o primary_ip loadbalancer
    

    Multiple addresses will be returned. Choose any one and set MANTA_URL to https://$that_ip.

  2. MANTA_USER will be the account you setup in "Set up a Manta Account" section.

  3. MANTA_KEY_ID will be the ssh key id you added in "Set up a Manta Account" section.

  4. If the key you used is in an environment that has not installed a certificate signed by a recognized authority you might see Error: self signed certificate errors. To fix this, add MANTA_TLS_INSECURE=true to your environment or shell config.

A final ~/.bashrc or ~/.bash_profile might look something like:

export MANTA_USER=poseidon
export MANTA_URL=https://<your-loadbalancer-ip>
export MANTA_TLS_INSECURE=true
export MANTA_KEY_ID=`ssh-keygen -l -f ~/.ssh/id_rsa.pub | awk '{print $2}' | tr -d '\n'`

Lastly test the CLI tools from your development machine:

$ echo "Hello, Manta" > /tmp/hello.txt
$ mput -f /tmp/hello.txt ~~/stor/hello-foo
.../stor/hello-foo          [=======================================================>] 100%      13B
$ mls ~~/stor/
hello-foo
$ mget ~~/stor/hello-foo
Hello, Manta

Networking configuration

The networking configuration file is a per-datacenter JSON file with several properties:

Property Kind Description
azs array of strings list of all availability zones (datacenters) participating in Manta in this region
this_az string string (in azs) denoting this availability zone
manta_nodes array of strings list of server uuid's for all servers participating in Manta in this AZ
admin object describes the "admin" network in this datacenter (see below)
manta object describes the "manta" network in this datacenter (see below)
nic_mappings object maps each server in manta_nodes to an object mapping each network name to the network interface on the server that should be tagged
mac_mappings object (deprecated) maps each server uuid from manta_nodes to an object mapping each network name ("admin", "manta") to the MAC address on that server over which that network should be created.
distribute_svcs boolean control switch over boot-time networking detection performed by manta-net.sh (see below)

"admin" and "manta" describe the networks that are built into Manta:

  • admin: the Triton administrative network
  • manta: the Manta administrative network, used for high-volume communication between all Manta services.

Each of these is an object with several properties:

Property Kind Description
network string Name for the Triton network object (usually the same as the network name)
nic_tag string NIC tag name for this network (usually the same as the network name)

Besides those two, each of these blocks has a property for the current availability zone that describes the "subnet", "gateway", "vlan_id", and "start" and "end" provisionable addresses.

nic_mappings is a nested object structure defining the network interface to be tagged for each server defined in manta_nodes, and for each of Manta's required networks. See below for an example of this section of the configuration.

Note: If aggregations are used, they must already exist in NAPI, and updating NIC tags on aggregations will require a reboot of the server in question.

The optional boolean distribute_svcs gives control to the operator over the boot-time networking detection that happens each time manta-net.sh is executed (which determines if the global zone SMF services should be distributed). For example, an operator has enabled boot-time networking in a datacenter after installing Manta, and subsequently would like to add some more storage nodes. For consistency, the operator can set distribute_svcs to true in order to force distribution of these global zone services.

Note: For global zone network changes handled by boot-time networking to take effect, a reboot of the node must be performed. See Triton's virtual networking documentation for more information on boot-time networking.

For reference, here's an example multi-datacenter configuration with one service node (aac3c402-3047-11e3-b451-002590c57864) and one storage node (445aab6c-3048-11e3-9816-002590c3f3bc):

{
  "this_az": "staging-1",

  "manta_nodes": [
    "aac3c402-3047-11e3-b451-002590c57864",
    "445aab6c-3048-11e3-9816-002590c3f3bc"
  ],
  "azs": [
    "staging-1",
    "staging-2",
    "staging-3"
  ],

  "admin": {
    "nic_tag": "admin",
    "network": "admin",
    "staging-1": {
      "subnet": "172.25.3.0/24",
      "gateway": "172.25.3.1"
    },
    "staging-2": {
      "subnet": "172.25.4.0/24",
      "gateway": "172.25.4.1"
    },
    "staging-3": {
      "subnet": "172.25.5.0/24",
      "gateway": "172.25.5.1"
    }
  },

  "manta": {
    "nic_tag": "manta",
    "network": "manta",
    "staging-1": {
      "vlan_id": 3603,
      "subnet": "172.27.3.0/24",
      "start": "172.27.3.4",
      "end": "172.27.3.254",
      "gateway": "172.27.3.1"
    },
    "staging-2": {
      "vlan_id": 3604,
      "subnet": "172.27.4.0/24",
      "start": "172.27.4.4",
      "end": "172.27.4.254",
      "gateway": "172.27.4.1"
    },
    "staging-3": {
      "vlan_id": 3605,
      "subnet": "172.27.5.0/24",
      "start": "172.27.5.4",
      "end": "172.27.5.254",
      "gateway": "172.27.5.1"
    }
  },

  "nic_mappings": {
    "aac3c402-3047-11e3-b451-002590c57864": {
      "manta": {
        "mac": "90:e2:ba:4b:ec:d1"
      }
    },
    "445aab6c-3048-11e3-9816-002590c3f3bc": {
      "manta": {
        "mac": "90:e2:ba:4a:32:71"
      },
      "mantanat": {
        "aggr": "aggr0"
      }
    }
  }
}

The deprecated mac_mappings can also be used in place of nic_mappings. Only one of nic_mappings or mac_mappings is supported per network configuration file.

In a multi-datacenter configuration, this would be used to configure the "staging-1" datacenter. There would be two more configuration files, one for "staging-2" and one for "staging-3".

manta-adm configuration

"manta-adm" is the tool we use both to deploy all of the Manta zones and then to provision new zones, deprovision old zones, or reprovision old zones with a new image. "manta-adm" also has commands for viewing what's deployed, showing information about compute nodes, and more, but this section only discusses the configuration file format.

A manta-adm configuration file takes the form:

{
    "COMPUTE_NODE_UUID": {
        "SERVICE_NAME": {
            "IMAGE_UUID": COUNT_OF_ZONES
        },
        "SHARDED_SERVICE_NAME": {
            "SHARD_NUMBER": {
                "IMAGE_UUID": COUNT_OF_ZONES
            },
        }
    },
}

The file specifies how many of each kind of zone should be deployed on each compute node. For most zones, the "kind" of zone is just the service name (e.g., "storage"). For sharded zones, you also have to specify the shard number.

After you've run manta-init, you can generate a sample configuration for a single-system install using "manta-adm genconfig". Use that to give you an idea of what this looks like:

$ manta-adm genconfig coal
{
    "<any>": {
        "nameservice": {
            "197e905a-d15d-11e3-90e2-6bf8f0ea92b3": 1
        },
        "postgres": {
            "1": {
                "92782f28-d236-11e3-9e6c-5f7613a4df37": 2
            }
        },
        "moray": {
            "1": {
                "ef659002-d15c-11e3-a5f6-4bf577839d16": 1
            }
        },
        "electric-moray": {
            "e1043ddc-ca82-11e3-950a-ff14d493eebf": 1
        },
        "storage": {
            "2306b44a-d15d-11e3-8f87-6b9768efe5ae": 2
        },
        "authcache": {
            "5dff63a4-d15c-11e3-a312-5f3ea4981729": 1
        },
        "storinfo": {
            "2ef81a09-ad04-445f-b4fe-1aa87ce4e54c": 1
        },
        "webapi": {
            "319afbfa-d15e-11e3-9aa9-33ebf012af8f": 1
        },
        "loadbalancer": {
            "7aac4c88-d15c-11e3-9ea6-dff0b07f5db1": 1
        },
        "ops": {
            "ab253aae-d15d-11e3-8f58-3fb986ce12b3": 1
        }
    }
}

This file effectively specifies all of the Manta components except for the platforms.

You can generate a configuration file that describes your current deployment with manta-adm show -s -j.

For a coal or lab deployment, your best bet is to save the output of manta-adm genconfig coal or manta-adm genconfig lab to a file and use that. This is what the manta-deploy-coal and manta-deploy-lab scripts do, and you may as well just use those.

Once you have a file like this, you can pass it to manta-adm update, which will show you what it will do in order to make the deployment match the configuration file, and then it will go ahead and do it. For more information, see "manta-adm help update".