Skip to content

Commit 6d7b8bb

Browse files
authored
mypv-wifi-meter: fix energy scale (evcc-io#17416)
1 parent 7eabc78 commit 6d7b8bb

File tree

1 file changed

+1
-1
lines changed

1 file changed

+1
-1
lines changed

templates/definition/meter/mypv-wifi-meter.yaml

+1-1
Original file line numberDiff line numberDiff line change
@@ -26,7 +26,7 @@ render: |
2626
address: 34 # 0x0022 sum of forward energy; unsigned, value=data/800, unit: kWh
2727
type: holding
2828
decode: uint32
29-
scale: 0.08
29+
scale: 0.00125
3030
currents:
3131
- source: modbus
3232
{{- include "modbus" . | indent 2 }}

0 commit comments

Comments