-
Notifications
You must be signed in to change notification settings - Fork 69
/
Copy pathIDS_ucms_prefab_pipes_IFC2x3.ids
237 lines (237 loc) · 8.36 KB
/
IDS_ucms_prefab_pipes_IFC2x3.ids
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
<?xml version="1.0" encoding="UTF-8" standalone="yes"?>
<ids:ids xmlns:ids="http://standards.buildingsmart.org/IDS" xmlns:xs="http://www.w3.org/2001/XMLSchema" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://standards.buildingsmart.org/IDS http://standards.buildingsmart.org/IDS/1.0/ids.xsd">
<ids:info>
<ids:title>Prefabrication of pipes - LOD200</ids:title>
<ids:copyright>buildingSMART International Ltd</ids:copyright>
<ids:description>This is an example implementation of the PDF exchange requirements for prefab pipes. Use-case can be found here: https://ucm.buildingsmart.org/use-case-details/1682/en and the PDF with requirements here: https://ucm.buildingsmart.org/uploads/use-cases/39fb5bd005525dbf048273aa7453557b0b84c4e99250e6ed8ce5c3370825725f/files/en/20210804094140_er-UC-Prefab-of-pipes-V1.2.0.0.pdf </ids:description>
<ids:date>2021-09-17</ids:date>
<ids:milestone>LOD200</ids:milestone>
</ids:info>
<ids:specifications>
<ids:specification ifcVersion="IFC2X3" name="mounting part">
<ids:applicability maxOccurs="unbounded">
<ids:entity>
<ids:name>
<ids:simpleValue>IFCDISCRETEACCESSORY</ids:simpleValue>
</ids:name>
</ids:entity>
</ids:applicability>
<ids:requirements>
<ids:property dataType="IFCTEXT">
<ids:propertySet>
<ids:simpleValue>ePset_Pipe</ids:simpleValue>
</ids:propertySet>
<ids:baseName>
<ids:simpleValue>medium</ids:simpleValue>
</ids:baseName>
<ids:value>
<xs:restriction base="xs:string">
<xs:enumeration value="cold water"/>
<xs:enumeration value="something else"/>
</xs:restriction>
</ids:value>
</ids:property>
<ids:property dataType="IFCTEXT">
<ids:propertySet>
<ids:simpleValue>ePset_Pipe</ids:simpleValue>
</ids:propertySet>
<ids:baseName>
<ids:simpleValue>material</ids:simpleValue>
</ids:baseName>
<ids:value>
<xs:restriction base="xs:string">
<xs:enumeration value="chrome steel 1.4401"/>
<xs:enumeration value="something else"/>
</xs:restriction>
</ids:value>
</ids:property>
<ids:property dataType="IFCLENGTHMEASURE">
<ids:propertySet>
<ids:simpleValue>ePset_Pipe</ids:simpleValue>
</ids:propertySet>
<ids:baseName>
<ids:simpleValue>pipe diameter</ids:simpleValue>
</ids:baseName>
<ids:value>
<xs:restriction base="xs:double">
<xs:minInclusive value="0.02"/>
<xs:maxInclusive value="0.06"/>
</xs:restriction>
</ids:value>
</ids:property>
<ids:property dataType="IFCTEXT">
<ids:propertySet>
<ids:simpleValue>ePset_Pipe</ids:simpleValue>
</ids:propertySet>
<ids:baseName>
<ids:simpleValue>component designation</ids:simpleValue>
</ids:baseName>
<ids:value>
<xs:restriction base="xs:string">
<xs:enumeration value="8000.18"/>
<xs:enumeration value="something else"/>
</xs:restriction>
</ids:value>
</ids:property>
<ids:property dataType="IFCTEXT" uri="https://www.igh.hr/en/reference/">
<ids:propertySet>
<ids:simpleValue>ePset_Pipe</ids:simpleValue>
</ids:propertySet>
<ids:baseName>
<ids:simpleValue>numbering system</ids:simpleValue>
</ids:baseName>
<ids:value>
<xs:restriction base="xs:string">
<xs:enumeration value="first option"/>
<xs:enumeration value="something else"/>
</xs:restriction>
</ids:value>
</ids:property>
<ids:property dataType="IFCTEXT">
<ids:propertySet>
<ids:simpleValue>ePset_Pipe</ids:simpleValue>
</ids:propertySet>
<ids:baseName>
<ids:simpleValue>Pipe system</ids:simpleValue>
</ids:baseName>
<ids:value>
<xs:restriction base="xs:string">
<xs:enumeration value="first option"/>
<xs:enumeration value="something else"/>
</xs:restriction>
</ids:value>
</ids:property>
</ids:requirements>
</ids:specification>
<ids:specification ifcVersion="IFC2X3" name="pipe fittings and pipes">
<ids:applicability maxOccurs="unbounded">
<ids:entity>
<ids:name>
<xs:restriction base="xs:string">
<xs:annotation>
<xs:documentation>This applies to either 'IFCFLOWFITTING' ór 'IFCFLOWSEGMENT'</xs:documentation>
</xs:annotation>
<xs:pattern value="IFCFLOWFITTING|IFCFLOWSEGMENT"/>
</xs:restriction>
</ids:name>
</ids:entity>
</ids:applicability>
<ids:requirements>
<ids:property dataType="IFCLABEL" uri="http://identifier.buildingsmart.org/uri/buildingsmart/ifc-4.3/prop/Manufacturer">
<ids:propertySet>
<ids:simpleValue>Pset_ManufacturerTypeInformation</ids:simpleValue>
</ids:propertySet>
<ids:baseName>
<ids:simpleValue>Manufacturer</ids:simpleValue>
</ids:baseName>
<ids:value>
<xs:restriction base="xs:string">
<xs:enumeration value="Manufacturer 1"/>
<xs:enumeration value="Manufacturer 2"/>
</xs:restriction>
</ids:value>
</ids:property>
<ids:property dataType="IFCTEXT">
<ids:propertySet>
<ids:simpleValue>ePset_Pipe</ids:simpleValue>
</ids:propertySet>
<ids:baseName>
<ids:simpleValue>medium</ids:simpleValue>
</ids:baseName>
<ids:value>
<xs:restriction base="xs:string">
<xs:enumeration value="cold water"/>
<xs:enumeration value="something else"/>
</xs:restriction>
</ids:value>
</ids:property>
<ids:property dataType="IFCTEXT">
<ids:propertySet>
<ids:simpleValue>ePset_Pipe</ids:simpleValue>
</ids:propertySet>
<ids:baseName>
<ids:simpleValue>material</ids:simpleValue>
</ids:baseName>
<ids:value>
<xs:restriction base="xs:string">
<xs:enumeration value="chrome steel 1.4401"/>
<xs:enumeration value="something else"/>
</xs:restriction>
</ids:value>
</ids:property>
<ids:property dataType="IFCLENGTHMEASURE">
<ids:propertySet>
<ids:simpleValue>ePset_Pipe</ids:simpleValue>
</ids:propertySet>
<ids:baseName>
<ids:simpleValue>pipe diameter</ids:simpleValue>
</ids:baseName>
<ids:value>
<xs:restriction base="xs:double">
<xs:minInclusive value="0.02"/>
<xs:maxInclusive value="0.06"/>
</xs:restriction>
</ids:value>
</ids:property>
<ids:property dataType="IFCTEXT">
<ids:propertySet>
<ids:simpleValue>ePset_Pipe</ids:simpleValue>
</ids:propertySet>
<ids:baseName>
<ids:simpleValue>component designation</ids:simpleValue>
</ids:baseName>
<ids:value>
<xs:restriction base="xs:string">
<xs:enumeration value="arc 45°"/>
<xs:enumeration value="something else"/>
</xs:restriction>
</ids:value>
</ids:property>
<ids:property uri="https://www.igh.hr/en/reference/" dataType="IFCLABEL">
<ids:propertySet>
<ids:simpleValue>ePset_Pipe</ids:simpleValue>
</ids:propertySet>
<ids:baseName>
<ids:simpleValue>numbering system</ids:simpleValue>
</ids:baseName>
<ids:value>
<xs:restriction base="xs:string">
<xs:annotation>
<xs:documentation>Allowed value should be 4 numbers, a dot, and two numbers again. For example '1111.11', '1232.23', etc. are valid. Invalid are '234.12', '2134.2', '23O2.34' (the O is an o not a 0).</xs:documentation>
</xs:annotation>
<xs:pattern value="[0-9][0-9][0-9][0-9]\.[0-9][0-9]"/>
</xs:restriction>
</ids:value>
</ids:property>
<ids:property dataType="IFCTEXT">
<ids:propertySet>
<ids:simpleValue>ePset_Pipe</ids:simpleValue>
</ids:propertySet>
<ids:baseName>
<ids:simpleValue>Pipe system</ids:simpleValue>
</ids:baseName>
<ids:value>
<xs:restriction base="xs:string">
<xs:enumeration value="first option"/>
<xs:enumeration value="something else"/>
</xs:restriction>
</ids:value>
</ids:property>
<ids:property dataType="IFCLENGTHMEASURE">
<ids:propertySet>
<ids:simpleValue>ePset_Pipe</ids:simpleValue>
</ids:propertySet>
<ids:baseName>
<ids:simpleValue>outside diameter_general</ids:simpleValue>
</ids:baseName>
<ids:value>
<xs:restriction base="xs:double">
<xs:minInclusive value="0.02"/>
<xs:maxInclusive value="0.06"/>
</xs:restriction>
</ids:value>
</ids:property>
</ids:requirements>
</ids:specification>
</ids:specifications>
</ids:ids>