https://www.broadcom.com/support/download-search/?dk=storcli
# General information
storcli64 show
# Controller details
storcli64 /cALL show all
# WIPE ALL DATA
storcli /cALL delete config force
# WIPE VIRTUAL DRIVES -- does not prompt!
storcli /c0 /vALL del
storcli /c0 /v1-11 del -- don't whack the "0" VD which is OS Mirror
storcli /c0 /v12 del
# CREATE OS RAID-1 (assume SMC enclosure @ 252)
storcli /c0 add vd r1 drives=252:0,252:1 pdcache=off WB NORA
# CREATE RAID-BOD (assume SMC enclosure @50 with 12 HDD)
storcli /c0 add vd each r0 drives=50:0-11 pdcache=off WB NORA
..for i in $(seq 0 11); do
.. storcli /c0 add vd r0 drives=50:$i pdcache=off WB NORA;
..done
# CREATE 2x RAID-6 (4+2 & 4+2)
storcli /c0 add vd r6 drives=50:0-5 pdcache=off WB nora
storcli /c0 add vd r6 drives=50:0,50:1,50:2,50:3,50:4,50:5 pdcache=off WB nora
storcli /c0 add vd r6 drives=50:6-11 pdcache=off WB nora
storcli /c0 add vd r6 drives=50:6,50:7,50:8,50:9,50:10,50:11 pdcache=off WB nora
# CREATE 1x RAID-6 (10+2)
storcli /c0 add vd r6 drives=50:0-11 pdcache=off WB nora
# Turn on/off write-back caching
storcli /cx/vx set wrcache=WT|WB|AWB
storcli /c0/v1 set wrcache=WB
# Detailed drive information
# show disks attached to enclosure 50, 252, ALL
storcli /cALL /e50 /sALL show
storcli /cALL /e252 /sALL show
storcli /cALL /eALL /sALL show
# Logical Drive / Virtual Disk infor
storcli64 /c0 /vall show
### APPENDIX
# we create JBOD LUNS with writeback caching and without readahead
# readahead can be done by the operating system
# someday if we detect journaling SSDs in the config, turn off WB caching
storcli /c0 add vd r0 drives=50:0 pdcache=off WB nora
**storcli /cx add vd each r0 [name=<VDNAME1>,..] [drives=e:s|e:s-x|e:s-x,y]
# same for RAID-6
storcli /c0 add vd r6 drives=50:6,50:7,50:8,50:9,50:10,50:11 pdcache=off WB nora
# INIT, eta 9+ hours for 6TB HDD
storcli /cALL /v2-3 start init full
storcli /cALL show jbod
storcli /cALL set jbod=on | storcli /cALL set jbod=off
*storcli /c0 set personality=RAID|HBA|JBOD
*storcli /c0 set personality behavior=JBOD|None
*storcli /c0 show jbodwritecache
*storcli /c0 set jbodwritecache=on|off|default
*storcli /c0 /e50 /s0-11 set jbod
*storcli /c0 /e252 /s0-1 set jbod
storcli /cx add JBOD [drives=e:s|e:s-x|e:s-x,y]
# RESET TO FACTORY DEFAULTS
storcli /cALL set factory defaults