#ifndef CONFIG_H
#define CONFIG_H
//=============================================================================
// USER CONFIGURATION SECTION
// Edit these settings according to your setup
//=============================================================================
// WiFi Settings (Required)
#define WIFI_SSID "Your WiFi Network Name" // Your WiFi network name
#define WIFI_PASSWORD "Your WiFi Password" // Your WiFi password
// HomeKit Settings
#define HOMEKIT_SETUP_PIN "12345678" // 8-digit code for HomeKit pairing
// Operating Mode
#define DEFAULT_MODE MODE_AUTO // System starts in this mode:
// MODE_AUTO: Automatic grid monitoring
// MODE_MANUAL: Manual control only
// MODE_OFF: System disabled
// GPIO Pin Configuration
#define GRID_MONITOR_PIN 32 // Pin to monitor grid power status
#define GENERATOR_MONITOR_PIN 33 // Pin to monitor generator running status
#define GENERATOR_POWER_PIN 25 // Pin to control generator power
#define GENERATOR_CHOKE_PIN 26 // Pin to control generator choke
#define GENERATOR_STARTER_PIN 27 // Pin to control generator starter motor
#define TRANSFER_SWITCH_PIN 14 // Pin to control transfer switch
// Maximum start attempts
#define MAX_START_ATTEMPTS 3
//=============================================================================
// TIMING CONFIGURATIONS (all values in milliseconds) 1000ms = 1 second
// Only modify these if you understand the implications
//=============================================================================
// Grid Power Monitoring
#define GRID_OUTAGE_CONFIRM_DELAY 10000 // How long to wait before confirming power outage
#define GRID_RESTORE_CONFIRM_DELAY 10000 // How long to wait before confirming power restoration
#define GRID_MONITOR_DEBOUNCE 10000 // Debounce time for grid status changes
// Generator Control Timings
#define POWER_STABILIZE_DELAY 2000 // Time to wait after turning on generator power
#define CHOKE_ENGAGE_DELAY 3000 // Time to wait after engaging choke
#define STARTER_CRANK_DURATION 3000 // How long to run the starter motor
#define START_MONITOR_DURATION 10000 // How long to wait for generator to start
#define RETRY_ATTEMPT_DELAY 5000 // Time between start attempts
// Engine Management
#define CHOKE_WARMUP_DELAY 3000 // Time before releasing choke
#define POST_CHOKE_WARMUP_DELAY 5000 // Additional warm-up after choke release
// Safety Delays
#define TRANSFER_SWITCH_DELAY 10000 // Time before switching power to generator
#define MODE_CHANGE_CHECK_INTERVAL 50 // How often to check for mode changes
#define MANUAL_START_PREP_DELAY 10000 // Delay before manual start
#endif