4 Infrastructure Capabilities, Metrics, and Catalogue

scope


Table of Contents

4.1 Capabilities and Metrics

4.1.1 Exposed vs Internal

The following pertains to the context of NFVI Capabilities, Metrics and Constraints, as discussed within this chapter.

Exposed: Refers to any mechanism (e.g., discovery, configuration, consumption, telemetry, some object, API, Interface, etc.) that exists in or pertains to, the domain of the NFVI and is made visible (aka “Exposed”) to a tenant and/or VNF in the workload domain. When an object is exposed to a given tenant or VNF, the scope of visibility within a given VNF is at the discretion of the specific VNF’s designer. From an Infra perspective, the Infra-resident object is simply being exposed to one or more virtual environments (i.e. VMs). It is then the responsibility of the kernel or supervisor/executive within the VM to control how, when and where the object is further exposed within the VM, with regard to permissions, security, etc. As the object(s) originate with the NFVI or Control Plane, they are by definition visible within those domains.

Internal: Effectively the opposite of Exposed; objects Internal to the NFVI, which are exclusively available for use by the NFVI and components within the NFVI control plane.

Exposed vs. Internal Scope

Figure 4-1: Exposed vs. Internal Scope

As illustrated in the figure above, objects designated as "Internal" are only visible within the area inside the blue oval (the NFVI), and only when the entity accessing the object has the appropriate permissions. Whereas objects designated as "Exposed" are potentially visible from both the area within the green oval (the Workload), as well as from within the NFVI, again provided the entity accessing the object has appropriate permissions.

Note: The figure above indicates the areas from where the objects are visible. It is not intended to indicate where the objects are instantiated. For example, the virtual resources are instantiated within the NFVI (the blue area), but are Exposed, and therefore are visible to the Workload, within the green area.

4.1.2 Exposed Infrastructure capabilities

This section describes a set of explicit NFVI capabilities and metrics that define an NFVI. These capabilities and metrics are well known to VNFs as they provide capabilities which VNFs rely on.

Note: It is expected that NFVI capabilities and metrics will evolve with time as more capabilities are added as technology enhances and matures.

4.1.2.1 Exposed resource capabilities

Table 4-1 below shows resource capabilities of NFVI. Those indicate resources offered to VNFs by NFVI.

Ref NFVI capability Unit Definition/Notes
e.nfvi.res.cap.001 #vCPU cores number Min, Max number of vCPU cores that can be assigned to a single VNF-C
e.nfvi.res.cap.002 Amount of RAM (MB) MB Min, Max memory in MB that can be assigned to a single VNF-C by NFVI.
e.nfvi.res.cap.003 Total amount of instance (ephemeral) storage (GB) GB Min, Max storage in GB that can be assigned to a single VNF-C by NFVI
e.nfvi.res.cap.004 # vNICs number Max number of vNIC interfaces that can be assigned to a single VNF-C by NFVI.
e.nfvi.res.cap.005 Total amount of external (persistent) storage (GB) GB Min, Max storage in GB that can be attached / mounted to VNF-C by NFVI.

Table 4-1: Exposed resource capabilities of NFVI.

4.1.2.2 Exposed performance optimisation capabilities

Table 4-2 shows possible performance optimisation capabilities that can be provided by NFVI. These indicate capabilities exposed to VNFs. Those capabilities need to be consumed by VNFs in a standard way.

Ref NFVI capability Unit Definition/Notes
e.nfvi.per.cap.001 CPU pinning support Yes/No Determining if NFVI support CPU pinning
e.nfvi.per.cap.002 NUMA support Yes/No Determining if NFVI support NUMA awareness
e.nfvi.per.cap.003 IPSec Acceleration Yes/No IPSec Acceleration
e.nfvi.per.cap.004 Crypto Acceleration Yes/No Crypto Acceleration
e.nfvi.per.cap.005 Transcoding Acceleration Yes/No Transcoding Acceleration
e.nfvi.per.cap.006 Programmable Acceleration Yes/No Programmable Acceleration

Table 4-2: Exposed performance optimisation capabilities of NFVI.

4.1.2.3 Exposed monitoring capabilities

Table 4-3 shows possible monitoring capabilities available by NFVI for VNFs.

Ref NFVI capability Unit Definition/Notes
e.nfvi.mon.cap.001 Monitoring of L2-7 data Yes/No Ability for VNF-C to monitor their own L2-L7 data.

Table 4-3: Exposed monitoring capabilities of NFVI.

4.1.3 Exposed Infrastructure metrics

The intent of those metrics is to be well known to VNFs.

4.1.3.1 Exposed performance metrics

The following shows performance metrics per VNF-C, vNIC or vCPU.

Ref NFVI metric Unit Definition/Notes
e.nfvi.per.met.001 Network throughput bits/s or packets/s Max throughput per vNIC (as aligned with ETSI GS NFV-TST 009 [2])
e.nfvi.per.met.002 Network latency second Max round trip time to vNIC (as aligned with ETSI GS NFV-TST 009 [2])
e.nfvi.per.met.003 Network Delay Variation second Max packet delay variation (a.k.a., jitter) of round trip time to vNIC (as aligned with ETSI GS NFV-TST 009 [2])
e.nfvi.per.met.004 Simultaneous active flows number Max simultaneous active L4 flows per vNIC before a new flow is dropped
e.nfvi.per.met.005 New flows rate flows/s Max new L4 flow rate per vNIC
e.nfvi.per.met.006 Storage throughput bytes/s or IO/s Max throughput per virtual block storage unit assigned to VNF-C
e.nfvi.per.met.007 Processing capacity test-specific Processing capacity test-specific score per vCPU

Table 4-4: Exposed performance metrics of NFVI.

4.1.4 Internal Infrastructure capabilities

This section covers a list of implicit NFVI capabilities and metrics that define the interior of NFVI. These capabilities and metrics determine how the NFVI behaves internally. They are hidden from VNFs (i.e. VNFs may not know about them) but they will have a big impact on the overall performance and capabilities of a given NFVI solution.

Note: It is expected that implicit NFVI capabilities and metrics will evolve with time as more capabilities are added as technology enhances and matures.

4.1.4.1 Internal resource capabilities

Table 4-5 shows resource capabilities of NFVI. These include capabilities offered to VNFs and resources consumed internally by NFVI.

Ref NFVI capability Unit Definition/Notes
i.nfvi.res.cap.001 Percentage of vCPU cores consumed by NFVI overhead in a compute node. % (of total available) Indicates the percentage of vCPU cores consumed (wasted) by NFVI components (including host OS) in a compute node.
i.nfvi.res.cap.002 Percentage of memory consumed by NFVI overhead in a compute node. % (of total available) Indicates the percentage of memory consumed (wasted) by NFVI components (including host OS) in a compute node.

Table 4-5: Internal resource capabilities of NFVI.

4.1.4.2 Internal SLA capabilities

Table 4-6 below shows SLA (Service Level Agreement) capabilities available by NFVI. These include capabilities required by VNFs as well as internal capabilities to NFVI. Application of these capabilities to a given workload is determined by its instance type (e.g. T-Shirt size).

Ref NFVI capability Unit Definition/Notes
i.nfvi.sla.cap.001 CPU overbooking 1:N This indicates the number of vCPU cores consumed (wasted) by NFVI components (including host OS) in a compute node.
i.nfvi.sla.cap.002 vNIC QoS Yes/No QoS enablement

Table 4-6: Internal SLA capabilities to NFVI.

4.1.4.3 Internal performance optimisation capabilities

Table 4-7 below shows possible performance optimisation capabilities that can be provided by NFVI. These include capabilities exposed to VNFs as well as internal capabilities to NFVI. These capabilities will be determined by the standard instance type used by VNF-C (VNF Component)

Ref NFVI capability Unit Definition/Notes
i.nfvi.per.cap.001 Huge page support Yes/No Determining if NFVI support huge pages

Table 4-7: Internal performance optimisation capabilities of NFVI.

4.1.4.4 Internal monitoring capabilities

Table 4-8 shows possible monitoring capabilities available by NFVI. The availability of these capabilities will be determined by the instance type used by the workloads.

Ref NFVI capability Unit Definition/Notes
i.nfvi.mon.cap.001 Host CPU usage Per Compute node. It needs to Maps to ETSI NFV-TST 008[1] clause 6, processor usage metric (NFVI exposed to VIM) and ETSI NFV-IFA 027 Mean Virtual CPU usage and Peak Virtual CPU usage (VIM exposed to VNFM).
i.nfvi.mon.cap.002 Virtual compute resource CPU usage QoS enablement
i.nfvi.mon.cap.003 Host CPU utilization Per Compute node. It needs to map to ETSI NFV-IFA 027 Mean Virtual CPU usage and Peak Virtual CPU usage (VIM, exposed to VNFM).
i.nfvi.mon.cap.004 Virtual compute resource CPU utilization Range (min, max) per VNF-C
i.nfvi.mon.cap.005 Monitoring of external storage IOPS Yes/No Transcoding Acceleration
i.nfvi.mon.cap.006 Monitoring of external storage throughput Yes/No Programmable Acceleration
i.nfvi.mon.cap.007 Monitoring of external storage capacity Yes/No

Table 4-8: Internal monitoring capabilities of NFVI.

4.1.4.5 Internal security capabilities

Ref NFVI capability Unit Definition/Notes
i.nfvi.sec.cap.001 VNF-C<->VNF-C memory isolation Yes/No Are VNF-C memories isolated from each other by hardware support?
i.nfvi.sec.cap.002 VNF-C -> Host Yes/No Can VNF-C access host memory?
i.nfvi.sec.cap.003 Host -> VNF-C Yes/No Can Host access VNF-C memory?
i.nfvi.sec.cap.004 External storage at-rest encryption Yes/No Is external storage encrypted at-rest?

Table 4-9: Internal security capabilities of NFVI.

4.1.5 Internal Infrastructure metrics

4.1.5.1 Internal performance metrics

The following table shows performance metrics per NFVI node.

Ref NFVI metrics Unit Definition/Notes
i.nfvi.per.met.001 Network throughput bits/s or packets/s Max throughput per node (aligned with ETSI GS NFV-TST 009 [2])
i.nfvi.per.met.002 Simultaneous active flows number Max simultaneous active L4 flows per node before a new flow is dropped
i.nfvi.per.met.003 New flows rate flows/s Max new L4 flow rate per node
i.nfvi.per.met.004 Processing capacity test-specific Processing capacity test-specific score per node
i.nfvi.per.met.005 Energy consumption W Maximum energy consumption of the node without hosting any VNF-C (but fully ready for it)
i.nfvi.per.met.006 Network energy efficiency W/bits/s Energy consumption for the node max network throughput, normalized to the bit rate
i.nfvi.per.met.007 Processing energy efficiency W/core Energy consumption during the node processing capacity measurement (i.nfvi.per.met.004), normalized to physical cores usable by VNF-C

Table 4-10: Internal performance metrics of NFVI.

It should be noted that energy-related metrics must only be considered for NFVI software implementations benchmarking on a same NFVI hardware implementation (since energy consumption may be very different for a same processor model due to foundry process spread).

4.1.5.2 Internal availability/reliability metrics

Editor Note: the following table should be reviewed to only consider and probably detail the recovery-related metrics ; indeed, availability and MTBF metrics do not seem consistent with expected testbed measurement duration]

Editor Note: This table needs to be reworked and clarified w/ clear explanations and assumptions stated.

Ref NFVI metric Unit Definition/Notes
i.nfvi.arl.met.001 Availability %
i.nfvi.arl.met.002 MTBF single node days Mean Time between Failure for single node
i.nfvi.arl.met.003 MTBF AZ days Mean Time between Failure for an AZ
i.nfvi.arl.met.004 Recovery time seconds

Table 4-11: Internal availability/reliability metrics of NFVI.

4.1.6 VIM capabilities.

Editor Note: This Section is still to be worked on.

4.1.7 VIM metrics.

4.1.7.1 Resources management metrics

Table 4-12 shows resource management metrics of VIM as aligned with ETSI GS NFV TST-012 [3].

Ref VIM metrics Unit Definition/Notes
vim.rmt.met.001 Time to create Virtual Compute for a given VNF Max ms
vim.rmt.met.002 Time to delete Virtual Compute of a given VNF Max ms
vim.rmt.met.003 Time to start Virtual Compute of a given VNF Max ms
vim.rmt.met.004 Time to stop Virtual Compute of a given VNF Max ms
vim.rmt.met.005 Time to pause Virtual Compute of a given VNF Max ms
vim.rmt.met.006 Time to create internal virtual network Max ms
vim.rmt.met.007 Time to delete internal virtual network Max ms
vim.rmt.met.008 Time to update internal virtual network Max ms
vim.rmt.met.009 Time to create external virtual network Max ms
vim.rmt.met.010 Time to delete external virtual network Max ms
vim.rmt.met.011 Time to update external virtual network Max ms
vim.rmt.met.014 Time to create external storage ready for use by VNF Max ms

Table 4-12: Resource management metrics of VIM.

4.2 Catalogue

Infrastructure exposes sets of capabilities, metrics, compute flavours, interface options, storage extensions, and acceleration capabilities to VNFs. Those sets are offered to VNFs in form of instance types with their corresponding options and extensions.

The idea of the infrastructure instances catalogue is to have a predefined set of instance types with a predefined set of compute flavours (sometimes referred to as T-shirt sizes) which VNF vendors use to build their VNFs. Each VNF uses one or more of those compute flavours (with one or more of offered instance types) to build its overall functionality as illustrated in Figure 4-2.

vnf_design

Figure 4-2: VNFs built against standard instance types and compute flavours.

4.2.1 Compute flavours

Flavours represent the compute, memory, storage capacity, and management network resource templates that are used to create the VMs on the compute hosts. Each VM instance is given a flavour (resource template), which determines the instance's core, memory and storage characteristics.

Flavours can also specify secondary ephemeral storage, swap disk, etc. A compute flavour geometry consists of the following elements:

Element Description
Name A descriptive name
Virtual compute resources (aka vCPUs) Number of virtual compute resources (vCPUs) presented to the instance.
Memory MB Instance memory in megabytes.
Ephemeral/Local Disk Specifies the size of an ephemeral data disk that exists only for the life of the instance. Default value is 0.
The ephemeral disk may be partitioned into boot (base image) and swap space disks.
Is Public Boolean value, whether flavor is available to all users or private to the project it was created in. Defaults to True.

Table 4-13: Flavour Geometry Specification.

4.2.1.1 Predefined Compute flavours

The intent of the following flavours list is to be comprehensive and yet effective to cover both IT and NFV workloads. The compute flavours are specified relative to the standardised “large” flavour. The standard “large” flavour configuration consists of 4 vCPUs, 8 GB of RAM and 80 GB of local disk, and the resulting instance will have a management interface of 1 Gbps. The “medium” flavour is half the size of a large and small is half the size of medium. The tiny flavour is a special sized flavour.

Note: Customised (Parameterized) flavours can be used in concession by operators and , if needed, are created using TOSCA, HEAT templates and/or VIM APIs.

.conf vCPU ("c") RAM ("r") Local Disk ("d") Management Interface
.tiny 1 512 MB 1 GB 1 Gbps
.small 1 2 GB 20 GB 1 Gbps
.medium 2 4 GB 40 GB 1 Gbps
.large 4 8 GB 80 GB 1 Gbps
.2xlarge* 8 16 GB 160 GB 1 Gbps
.4xlarge* 16 32 GB 320 GB 1 Gbps

Table 4-14: Predefined Compute flavours.

*These compute flavours are intended to be used for transitional purposes and VNF vendors are expected to consume smaller flavours and adopt micro server's designs for their VNFs

4.2.2 Network Interface Specifications

The network interface specifications extend the flavour customization to specify the network interface “n” followed by the interface bandwidth (in Gbps) and an alphabetic character defining the number of interfaces with that bandwidth; multiple network interface bandwidths, where network interfaces of different bandwidths exist, can be specified by repeating the “n” option.

<network interface bandwidth option> :: <”n”><number (bandwidth in Gbps)>< # of interfaces of that bandwidth>
<number of interfaces> :: <”” | “D” | “T” | “Q” | “P” | “H”> 
where “” represents 1x, “D” 2x, “T” 3x, “Q” 4x, “p” 5x and “H” 6x interfaces of the given bandwidth.
Virtual network interface option Description (Bandwidth in Gbps)
n1, n10, n1T, n1Q, n1P, n1H 1x 1, 2x 1, 3x 1, 4x 1, 5x 1, 6x 1 Gbps
n10, n10D, n10T, n10Q, n10P, n10H 1x 10, 2x 10, 3x 10, 4x 10, 5x 10, 6x 10 Gbps
n25, n25D, n25T, n25Q, n25P, n25H 1x 25, 2x 25, 3x 25, 4x 25, 5x 25, 6x 25 Gbps
n50, n50D, n50T, n50Q, n50P, n50H 1x 50, 2x 50, 36x 50, 4x 50, 5x 50, 6x 50 Gbps
n100, n100D, n100T, n100Q, n100P, n100H 1x 100, 2x 100, 3x 100, 4x 100, 5x 100, 6x 100 Gbps

Table 4-15: Virtual Network Interface Specification Examples.

4.2.3 Storage Extensions

Multiple non-ephemeral storage volumes can be attached to virtual computes for persistent data storage. Each of those volumes can be configured with the required performance category.

.conf Read IO/s Write IO/s Read Throughput (MB/s) Write Throughput (MB/s)
.bronze Up to 3K Up to 15K Up to 180 Up to 120
.silver Up to 60K Up to 30K Up to 1200 Up to 400
.gold Up to 680K Up to 360K Up to 2650 Up to 1400

Table 4-16: Storage Performance Profiles.

4.2.3.1 Available storage extensions

These are non-ephemeral storage extensions that can be provided to VNFs for persistent data storage. More than one storage extension can be provided to a single VNF-C.

.conf capacity Read IOPS Write IOPS Read Throughput (MB/s) Write Throughput (MB/s)
.bronze1 100GB Up to 3K Up to 15K Up to 180 Up to 120
.bronze2 200GB Up to 3K Up to 15K Up to 180 Up to 120
.bronze3 300GB Up to 3K Up to 15K Up to 180 Up to 120
.silver1 100GB Up to 60K Up to 30K Up to 1200 Up to 400
.silver2 200GB Up to 60K Up to 30K Up to 1200 Up to 400
.silver3 300GB Up to 60K Up to 30K Up to 1200 Up to 400
.gold1 100GB Up to 680K Up to 360K Up to 2650 Up to 1400
.gold2 200GB Up to 680K Up to 360K Up to 2650 Up to 1400
.gold3 300GB Up to 680K Up to 360K Up to 2650 Up to 1400

Table 4-17: Storage extensions for compute flavours.

4.2.4 Instance types

4.2.4.1 B Instances (Basic)

This instance type is intended to be used for both IT workloads as well as NFV workloads. It has limited IO capabilities (up to 10Gbps Network interface) with a wide range of compute flavours. This instance type is intended to be available in any data centre within any operator's network.

4.2.4.2 N Instances (Network Intensive)

This instance type is intended to be used for those applications that has high network throughput requirements (up to 50Gbps). This instance type is more intended for VNFs and is expected to be available in regional (distributed) data centres and more towards the access networks.

4.2.4.2.1 Network Acceleration Extensions

N instance types can come with Network Acceleration extensions to assist VNFs offloading some of their network intensive operations to hardware. The list below is preliminary and is expected to grow as more network acceleration resources are developed and standardized.

Interface types are aligned with ETSI NFV IFA 002 [4].

.conf Interface type Description
.il-ipsec virtio-ipsec* In-line IPSec acceleration
.la-crypto virtio-crypto Look-Aside encryption/decryption engine

Table 4-18: Acceleration extensions for N instance type.

*Need to work with relevant open source communities to create missing interfaces.

4.2.4.3 C Instances (Compute Intensive)

This instance type is intended to be used for those applications that has high compute requirements and can take advantage of acceleration technologies such as GPU, FPGA, etc. This instance type is intended to be available in local data centers and more towards the Edge of the network.

4.2.4.3.1 Compute acceleration extensions

C instance types can come with compute acceleration extensions to assist VNFs/VAs offloading some of their compute intensive operations to hardware. The list below is preliminary and is expected to grow as more compute acceleration resources are developed and standardized.

.conf Interface type Description
.la-trans virtio-trans* Look-Aside Transcoding acceleration
.la-programmable virtio-programmable Look-Aside programmable acceleration

Table 4-19: Acceleration extensions for C instance type.

*Need to work with relevant open source communities to create missing interfaces.

4.2.4.4 Network Interface Options

Table 4-8 below shows the various network interfaces options (from Table 4-3) are available for which profile type (Up to 6 interfaces are possible).

Virtual interface option* Basic Type Network Intensive Type Compute Intensive Type
n1, n10, n1T*, n1Q*, n1P*, n1H* Y N N
n10, n10D, n10T*, n10Q*, n10P*, n10H* Y Y Y
n25, n25D, n25T*, n25Q*, n25P*, n25H* N Y Y
n50, n50D, n50T*, n50Q*, n50P*, n50H* N Y Y
n100, n100D, n100T*, n100Q*, n100P*, n100H* N Y N

Table 4-20: Virtual NIC interfaces options

*These options are intended to be used for transitional purposes. VNFs are expected to use minimum number of interfaces and adopt micro-servers design principles.

4.2.5 Instance capabilities mapping.

Ref B Instance N Instance C Instance Notes
e.nfvi.res.cap.001 As per selected <flavour> As per selected <flavour> As per selected <flavour> Exposed resource capabilities as per Table 4-1.
e.nfvi.res.cap.002 As per selected <flavour> As per selected <flavour> As per selected <flavour>
e.nfvi.res.cap.003 As per selected <flavour> As per selected <flavour> As per selected <flavour>
e.nfvi.res.cap.004 As per selected As per selected As per selected
e.nfvi.res.cap.005 As per selected As per selected As per selected
e.nfvi.per.cap.001 No Yes Yes Exposed performance capabilities as per Table 4-2.
e.nfvi.per.cap.002 No Yes No
e.nfvi.per.cap.003 No Yes (if offered) No
e.nfvi.per.cap.004 No Yes (if offered) No
e.nfvi.per.cap.005 No No Yes (if offered)
e.nfvi.per.cap.006 No No Yes (if offered)
e.nfvi.mon.cap.001 No Yes No Exposed monitoring capabilities as per Table 4-3.
i.nfvi.sla.cap.001 1:4 1:1 1:1 Internal SLA capabilities as per Table 4-6.
i.nfvi.sla.cap.002 No Yes Yes
i.nfvi.per.cap.001 No Yes No Internal performance capabilities as per Table 4-7.
i.nfvi.mon.cap.001 Yes Yes Yes Internal monitoring capabilities as per Table 4-8.
i.nfvi.mon.cap.002 Yes Yes Yes
i.nfvi.mon.cap.003 Yes Yes Yes
i.nfvi.mon.cap.004 Yes Yes Yes
i.nfvi.mon.cap.005 Yes No Yes
i.nfvi.mon.cap.006 Yes No Yes
i.nfvi.mon.cap.007 Yes No Yes
i.nfvi.sec.cap.001 Yes Yes Yes Internal security capabilities as per Table 4-9.
i.nfvi.sec.cap.002 No No No
i.nfvi.sec.cap.003 Yes Yes Yes
i.nfvi.sec.cap.004 Yes Yes Yes

Table 4-21: Mapping of NFVI capabilities to instance types.

4.2.6 Instance metrics mapping.

Comment: To be worked on.

4.2.7 One stop shop

4.2.7.1 Naming convention

An entry in the infrastructure profile catalogue can be referenced using the following naming convention.

B/N/C <I opt> . <flavour> . <S ext> . <A ext>

Whereas:

  • B/N/C: specifies the instance type (Basic, Network Intensive, and Compute Intensive)
  • <I opt>: specifies the interface option of the instant.
  • <flavour>: specifies the compute flavour.
  • <S ext>: specifies an optional storage extension.
  • <A ext>: specifies an optional acceleration extension for either N or H instance types.

one_stop_shop

Figure 4-3: Infrastructure Instances catalogue.