ArtNet Binary Format

The data saved by ArtNet Recorder is saved in a proprietary binary format.

The saved binary data is divided into Header and Body, with the Header containing binary identification information and version information, and the Body containing the actual data.

Header Section

The Header consists of the following 16 bytes.

Field Name Size Description
1 ID[4] int8 Identifier, 4 characters fixed to \0xFF, 0x44, 0x4D, 0x58
2 Version int8 Binary Encode Version (currently 0x02)
3 CompressType int8 Compression format of the Body section
- 0x00: Uncompressed
- 0x01: Deflate
4 BodyEncodeType int8 Body Encode Type
- 0x00: DMX
- 0x00: DMX Packet (only supported for Deserialize)
- 0x03: Universe And DMX Values
5 Reserved[9] int8 Reserved area (filled with 0x00)

Body Section

The Body records DMX data in the following format until the end of the file.

Field Name Size Description
1 Timestamp int64 Data timestamp (milliseconds)
2 Universe int16 Universe number
3 Length int16 Length of DMX data
4 Data int8[] DMX data. The length is specified by "Field 3 Length"

Note

The length of the DMX data recorded in the Body is specified by the Length field and is not fixed.

Note

The Body section is compressed in the compression format specified by the CompressType field of the Header. Therefore, appropriate compression/decompression processing is required during Serialize/Deserialize.