Logs a redundant phase fault error for a voltage regulator. This action should be executed if a fault is detected during phase_fault_detection for the regulator.
A regulator may contain one or more redundant phases:
- An "N+2" regulator has two redundant phases
- An "N+1" regulator has one redundant phase
A phase fault occurs when a phase stops functioning properly. The redundancy level of the regulator is reduced.
The phase fault type indicates the level of redundancy remaining after the fault has occurred:
Type | Description |
---|---|
n+1 | An "N+2" regulator has lost one redundant phase. The regulator is now at redundancy level "N+1". |
n | Regulator has lost all redundant phases. The regulator is now at redundancy level N. |
If additional data about the fault was previously captured using i2c_capture_bytes, that data will be stored in the error log.
Name | Required | Type | Description |
---|---|---|---|
type | yes | string | Phase fault type. Specify one of the following: "n+1", "n". |
true
{
"log_phase_fault": {
"type": "n+1"
}
}