Issue
In most parameter sets we define "Positive/Negative electrode charge transfer coefficient", which is set to 0.5. This parameter actually is not used anywhere, which is confusing. The actual parameter used in AsymmetricButlerVolmer is "Positive/Negative electrode Butler-Volmer transfer coefficient", but as far as I can tell AsymmetricButlerVolmer is not used in any of the models.
Proposed solution
Short term:
- Remove the
"Positive/Negative electrode charge transfer coefficient" from all parameter sets.
Longer term (needs discussion/separate issue):
- Make AsymmetricButlerVolmer the default with the (right) charge transfer coefficient defined as 0.5 in the parameter sets (behaviour should be the same as we have now, not sure how performance will be affected).
Issue
In most parameter sets we define
"Positive/Negative electrode charge transfer coefficient", which is set to 0.5. This parameter actually is not used anywhere, which is confusing. The actual parameter used inAsymmetricButlerVolmeris"Positive/Negative electrode Butler-Volmer transfer coefficient", but as far as I can tellAsymmetricButlerVolmeris not used in any of the models.Proposed solution