I'm getting json files with signal or noise as 999. I suspect something is wrong, but it's difficult to tell what based on the available information.

Examples:

{
  "freq": 460125000,
  "freq_error": -31,
  "signal": 999,
  "noise": -50,
  "source_num": 3,
  "recorder_num": 42,
  "tdma_slot": 0,
  "phase2_tdma": 0,
  "start_time": 1738480876,
  "stop_time": 1738480879,
  "emergency": 0,
  "priority": 0,
  "mode": 0,
  "duplex": 0,
  "encrypted": 0,
  "call_length": 1,
  "talkgroup": 170,
  "talkgroup_tag": "West PD S-2(Coraopolis)",
  "talkgroup_description": "",
  "talkgroup_group_tag": "Police Dispatch",
  "talkgroup_group": "Allegheny County",
  "audio_type": "analog",
  "short_name": "conv",
  "freqList": [
    {
      "freq": 460125000,
      "time": 1738480876,
      "pos": 0.0,
      "len": 1.0439375,
      "error_count": 50,
      "spike_count": 999
    }
  ],
  "srcList": [
    {
      "src": -1,
      "time": 1738480876,
      "pos": 0.0,
      "emergency": 0,
      "signal_system": "",
      "tag": ""
    }
  ]
}
{
  "freq": 470437500,
  "freq_error": -4,
  "signal": -56,
  "noise": 999,
  "source_num": 9,
  "recorder_num": 52,
  "tdma_slot": 0,
  "phase2_tdma": 0,
  "start_time": 1738510990,
  "stop_time": 1738511278,
  "emergency": 0,
  "priority": 0,
  "mode": 0,
  "duplex": 0,
  "encrypted": 0,
  "call_length": 180,
  "talkgroup": 99,
  "talkgroup_tag": "West EMS Dispatch Identified",
  "talkgroup_description": "",
  "talkgroup_group_tag": "EMS Dispatch",
  "talkgroup_group": "Allegheny Country",
  "audio_type": "analog",
  "short_name": "conv",
  "freqList": [
    {
      "freq": 470437500,
      "time": 1738510990,
      "pos": 0.0,
      "len": 180.0841875,
      "error_count": 999,
      "spike_count": 56
    }
  ],
  "srcList": [
    {
      "src": 4221,
      "time": 1738510990,
      "pos": 0.0,
      "emergency": 0,
      "signal_system": "",
      "tag": ""
    }
  ],
  "multimon_ng": []
}

(I add the multimon_ng key but I didn't manipulate the noise or signal)

@xmleger
Copy link

xmleger commented Feb 4, 2025

I am seeing similar issues on my setup as well.

I was attributing it to local noise intrusion and had been mitigating alot of it by increasing the minduration to around 1 or 1.5 seconds. A few still occasionally get through though with the audio sounding similar to the noise captured if the squelch is set too low.

If it is an intermittent noise intrusion issue and it is generally always a 999db "signal" captured, would setting some high threshold cutoff for signals (really anything over +40 or +50db would probably be suspect) work to curtail this kind of problem?

@ZeroChaos-
Copy link
Author

Given the issue reported is for signal and noise of 999 my suspicion is the opposite of yours. I suspect that it an initialization value and the real value was never set for some reason.

@tadscottsmith
Copy link
Contributor

I'm not sure yet why they aren't always getting set to but the 999 is coming from DB_UNSET which is the default value when the recorders start/restart.

const int DB_UNSET = 999;