Notifications
You must be signed in to change notification settings - Fork 12
/
Copy pathbuderus-km271_en.yaml
473 lines (434 loc) · 13.6 KB
/
buderus-km271_en.yaml
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
# This is the configuration, I've put on the board.
# If you apply voltage to it, the green LED D! serves as status led2
# usually blinking with around 1 Hz. If you press button USER 1, it will
# toggle green led D2.
# To upload a new firmware, search for the "Fallback Hotspot" WiFi and
# log in with password "Z8zfajgxVvNw". It could take up to a minute for
# the fallack AP to be enabled when not able to connect to the "test"
# wifi network. So, if status is blinking, give it a minute to show up.
substitutions:
name: "km271-for-friends"
esphome:
name: "${name}"
# Automatically add the mac address to the name
# so you can use a single firmware for all devices
name_add_mac_suffix: true
platformio_options:
upload_speed: 921600
#board_build.f_flash: 80000000L
#board_build.partitions: "default_8MB.csv
#upload_flash_size: "8MB"
# This will allow for (future) project identification,
# configuration and updates.
project:
name: the78mole.km271-wifi
version: "1.0"
esp32:
board: esp32dev
framework:
type: arduino
# Enable logging
logger:
# Enable Home Assistant API
api:
ota:
platform: esphome
# password: "xxx"
wifi:
# ssid: "test"
# password: "testtest"
# Enable fallback hotspot (captive portal) in case wifi connection fails
ap:
ssid: "Fallback Hotspot"
password: "Z8zfajgxVvNw"
dashboard_import:
package_import_url: github://the78mole/esphome_components/components/km271_wifi/km271-for-friends.yaml@main
captive_portal:
# keep_user_credentials: true
uart:
id: uart_bus
tx_pin: GPIO2
rx_pin: GPIO4
baud_rate: 2400
external_components:
# - source:
# type: local
# path: my_components/components
# components: [ km271_wifi ]
- source: github://the78mole/esphome_components@main
components: [ km271_wifi ]
esp32_improv:
authorizer: improvble
authorized_duration: 120s
status_indicator: led3
identify_duration: 60s
improv_serial:
status_led:
id: ledgn1
pin:
number: GPIO21
inverted: true
km271_wifi:
- id: budoil
uart_id: uart_bus
binary_sensor:
- platform: gpio
id: improvble
name: "USER 2"
pin:
number: GPIO27
inverted: true
mode:
input: true
pullup: true
# Above is all the "give-away hardware suggestion stuff"
# It is the place for cleanup of to reduce flash footprint, like:
# improv, captive portal, dashboard_import,...)
##################################################################
##################################################################
# Below is the real examle stuff
- platform: km271_wifi
# Betriebswerte 1 HC1
heating_circuit_1_switch_off_optimization:
name: "HC1 Switch-off Optimization"
heating_circuit_1_switch_on_optimization:
name: "HC1 Switch-on Optimization"
heating_circuit_1_automatic:
name: "HC1 Automatic"
heating_circuit_1_ww_priority_processing:
name: "HC1 Hot Water priority"
heating_circuit_1_screed_drying:
name: "HC1 Screed Drying"
heating_circuit_1_holiday:
name: "HC1 Holiday"
heating_circuit_1_antifreeze:
name: "HC1 Antifreeze"
heating_circuit_1_manually:
name: "HC1 Manual"
# Betriebswerte 1 HC1
heating_circuit_1_summer:
name: "HC1 Summer Mode"
heating_circuit_1_day:
name: "HC1 Day Mode"
heating_circuit_1_no_comm_with_rc:
name: "HC1 No Communication with Remote Controller"
heating_circuit_1_rc_faulty:
name: "HC1 Remote Controller Failure"
heating_circuit_1_flow_sensor_error:
name: "HC1 Flow Sensor Error"
heating_circuit_1_max_flow:
name: "HC1 Maximum Flow Time" #???
heating_circuit_1_external_fault_input:
name: "HC1 External Fault Input"
# Betriebswerte 2 HC2
heating_circuit_2_switch_off_optimization:
name: "HC2 Switch-off Optimization"
heating_circuit_2_switch_on_optimization:
name: "HC2 Switch-on Optimization"
heating_circuit_2_automatic:
name: "HC2 Automatic"
heating_circuit_2_ww_priority_processing:
name: "HC2 Hot Water priority"
heating_circuit_2_screed_drying:
name: "HC2 Screed Drying"
heating_circuit_2_holiday:
name: "HC2 Holiday"
heating_circuit_2_antifreeze:
name: "HC2 Antifreeze"
heating_circuit_2_manually:
name: "HC2 Manual"
# Betriebswerte 2 HC1
heating_circuit_2_summer:
name: "HC2 Summer Mode"
heating_circuit_2_day:
name: "HC2 Day Mode"
heating_circuit_2_no_comm_with_rc:
name: "HC2 No Communication with Remote Controller"
heating_circuit_2_rc_faulty:
name: "HC2 Remote Controller Failure"
heating_circuit_2_flow_sensor_error:
name: "HC2 Flow Sensor Error"
heating_circuit_2_max_flow:
name: "HC2 Maximum Flow Time" #???
heating_circuit_2_external_fault_input:
name: "HC2 External Fault Input"
# Betriebswerte 1 DHW
ww_automatic:
name: "DHW Automatic"
ww_disinfection:
name: "WW Disinfection"
ww_reload:
name: "DHW Reload"
ww_holiday:
name: "DHW Holiday"
ww_error_disinfection:
name: "DHW Disinfektion Error"
ww_error_sensor:
name: "DHW Sensor Error"
ww_error_stays_cold:
name: "DHW Error DHW Stays cold"
ww_error_anode:
name: "DHW Anode failure"
# Betriebswerte 2 DHW
ww_loading:
name: "DHW Loading"
ww_manually:
name: "DHW Manual"
ww_reloading:
name: "DHW Reloading"
ww_switch_off_optimization:
name: "DHW Switch-off Optimization"
ww_switch_on_optimization:
name: "DHW Switch-on Optimization"
ww_day_mode:
name: "DHW Day Mode"
ww_post_processing:
name: "DHW Night Mode"
ww_priority_processing:
name: "DHW Priority Switching"
# Kesselfehler
error_burner_malfunction:
name: "FBurner Failure"
error_boiler_sensor:
name: "Boiler Sensor Error"
error_additional_sensor:
name: "Additional Sensor Error"
error_boiler_stays_cold:
name: "Boiler Stays Cold"
error_exhaust_gas_sensor:
name: "Exhaust Gas Sensor Error"
error_exhaust_gas_over_limit:
name: "FExhaust Gas Over Limit Error"
error_safety_chain_released:
name: "Safety Chain Error"
error_external_disturbance:
name: "External Disturbances Error"
# Kesselbetrieb
boiler_emission_test:
name: "Boiler Emission Test"
boiler_1st_stage_operation:
name: "Boiler Operation 1st Stage"
boiler_protection:
name: "Boiler Protection"
boiler_under_operation:
name: "Boiler in Operation"
boiler_performance_free:
name: "Boiler Performance Free"
boiler_performance_high:
name: "Boiler Performance High"
boiler_2st_stage_operation:
name: "Boiler Operation 2nd Stage"
boiler_actuation:
name: "Burner Control"
#Alarmstatus
alarm_exhaust_gas_sensor:
name: "Exhaust Gas Sensor Alarm"
alarm_boiler_flow_sensor:
name: "Boiler Flow Sensor Alarm"
alarm_burner:
name: "Burner Alarm"
alarm_heating_circuit_2_flow_sensor:
name: "HC2 Flow Sensor Alarm"
#Other stuff
load_pump_running:
name: "Loading Pump Operational"
circulation_pump_running:
name: "Circulation Pump Operational"
solar_pump_lowering:
name: "Solar Pump Lowering"
output:
- platform: gpio
id: led3
#name: LED3_Yellow
pin:
number: 23
mode: OUTPUT
inverted: true
- platform: gpio
id: led4
#name: LED4_Red
pin:
number: 25
mode: OUTPUT
inverted: true
button:
- platform: restart
name: "KM271-WiFi Restart"
- platform: template
name: "KM271 WW-Bereitung Aus"
on_press:
- lambda:
uint8_t command[] = {0x0C, 0x0E, 0x00, 0x65, 0x65, 0x65, 0x65, 0x65};
budoil->writer.enqueueTelegram(command, 8);
- platform: template
name: "KM271 WW-Bereitung Ein"
on_press:
- lambda:
uint8_t command[] = {0x0C, 0x0E, 0x01, 0x65, 0x65, 0x65, 0x65, 0x65};
budoil->writer.enqueueTelegram(command, 8);
- platform: template
name: "KM271 WW-Bereitung Auto"
on_press:
- lambda:
uint8_t command[] = {0x0C, 0x0E, 0x02, 0x65, 0x65, 0x65, 0x65, 0x65};
budoil->writer.enqueueTelegram(command, 8);
number:
- platform: km271_wifi
config_ww_temperature:
name: "Hot Water Temperature Day"
mode: slider
config_frost_switch_temperature:
name: "Frost Switching Temperature"
mode: slider
config_heating_circuit_1_room_target_temperature_night:
name: "HC1 Target Room Temperature Night"
mode: slider
config_heating_circuit_1_room_target_temperature_day:
name: "HC1 Target Room Temperature Day"
mode: slider
config_heating_circuit_1_holiday_target_temperature:
name: "Holiday Temperature"
mode: slider
config_heating_circuit_1_flow_temperature_max:
name: "HC1 Maximum Heating Circuit Temperature"
mode: slider
config_heating_circuit_1_design_temperature:
name: "HC1 Design Temperature"
mode: slider
config_heating_circuit_1_room_temperature_offset:
name: "HC1 Room Temperature Offset"
mode: slider
config_heating_circuit_1_holiday_days:
name: "HC1 Holiday Days"
mode: slider
config_heating_circuit_2_room_target_temperature_night:
name: "HC2 Target Room Temperature Night"
mode: slider
config_heating_circuit_2_room_target_temperature_day:
name: "HC2 Target Room Temperature Day"
mode: slider
config_heating_circuit_2_holiday_target_temperature:
name: "Holiday Temperaturer"
mode: slider
config_heating_circuit_2_flow_temperature_max:
name: "HC2 Maximum Heating Circuit Temperature"
mode: slider
config_heating_circuit_2_design_temperature:
name: "HC2 Design Temperature"
mode: slider
config_heating_circuit_2_room_temperature_offset:
name: "HC2 Room Temperature Offset"
mode: slider
config_heating_circuit_2_holiday_days:
name: "HC2 Holiday Day"
mode: slider
select:
- platform: km271_wifi
config_ww_operation_mode:
name: "Hot Water Operating Mode"
config_ww_circular_pump_interval:
name: "WHot Water Circulation Pump Interval"
config_heating_circuit_1_summer_winter_switch_temperature:
name: "HC1 Summer Winter Changeover Temperature"
config_heating_circuit_1_operation_mode:
name: "HC1 Operation Mode"
config_heating_circuit_1_lowering_type:
name: "HC1 Lowering Type"
config_heating_circuit_1_heating_system_type:
name: "HC1 Heating System"
config_heating_circuit_1_heating_program:
name: "HC1 Heating Program"
config_heating_circuit_2_summer_winter_switch_temperature:
name: "HC2 Summer Winter Changeover Temperature"
config_heating_circuit_2_operation_mode:
name: "HC2 Operation Mode"
config_heating_circuit_2_lowering_type:
name: "HC2 Lowering Type"
config_heating_circuit_2_heating_system_type:
name: "HC2 Heating System"
config_heating_circuit_2_heating_program:
name: "HC2 Heating Program"
sensor:
- platform: km271_wifi
heating_circuit_1_flow_target_temperature:
name: "HC1 Target Flow Temperature"
heating_circuit_1_flow_temperature:
name: "HC1 Flow Temperature"
heating_circuit_1_room_target_temperature:
name: "HC1 Target Room Temperature"
heating_circuit_1_room_temperature:
name: "HC1 Actual Room Temperature"
heating_circuit_1_pump_power:
name: "HC1 Pump Power"
heating_circuit_1_mixer_position:
name: "HC1 Mixer Position"
heating_circuit_1_curve_p10:
name: "HC1 Heating Curve +10 °C"
heating_circuit_1_curve_0:
name: "HC1 Heating Curve 0 °C"
heating_circuit_1_curve_n10:
name: "HC1 Heating Curve -10 °C"
heating_circuit_2_flow_target_temperature:
name: "HC2 Target Flow Temperature"
heating_circuit_2_flow_temperature:
name: "HC2 Flow Temperature"
heating_circuit_2_room_target_temperature:
name: "HC2 Target Room Temperature"
heating_circuit_2_room_temperature:
name: "HC2 Actual Room Temperature"
heating_circuit_2_pump_power:
name: "HC2 Pump Power"
heating_circuit_2_mixer_position:
name: "HC2 Mixer Position"
heating_circuit_2_curve_p10:
name: "HC2 Heating Curve +10 °C"
heating_circuit_2_curve_0:
name: "HC2 Heating Curve 0 °C"
heating_circuit_2_curve_n10:
name: "HC2 Heating Curve -10 °C"
ww_target_temperature:
name: "Hot Water Target Temperature"
ww_temperature:
name: "Actual Hot Water temperature"
boiler_target_temperature:
name: "Boiler Target Temperature"
boiler_temperature:
name: "Boiler Actual Temperature"
boiler_turn_on_temperature:
name: "Burner Switch-on Temperature"
boiler_turn_off_temperature:
name: "Burner Switch-off Temperature"
exhaust_gas_temperature:
name: "Exhaust Gas Temperature"
outdoor_temperature:
name: "Outside Temperature"
attenuated_outdoor_temperature:
name: "Attenuated Outdoor Temperature"
boiler_runtime_1:
name: "Burner Runtime 1"
boiler_runtime_2:
name: "Burner Runtime 2"
- platform: wifi_signal
name: "KM217 WiFi Signal Sensor"
update_interval: 60s
- platform: adc
pin: 36
unit_of_measurement: "V"
name: "KM217 5V Supply"
accuracy_decimals: 2
update_interval: 5s
attenuation: 6dB
filters:
- multiply: 28.1826
- throttle_average: 60s
switch:
- platform: gpio
name: LED2_Green
pin:
number: 22
mode: OUTPUT
inverted: true
text_sensor:
- platform: km271_wifi
firmware_version:
name: "Firmware Version Control"