Notifications
You must be signed in to change notification settings - Fork 2
/
Copy pathSettings.h
150 lines (123 loc) · 5.48 KB
/
Settings.h
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
#ifndef SETTINGS_H
#define SETTINGS_H
// Enable debug prints to serial monitor
#define MY_DEBUG
// Enable and select radio type attached
#define MY_RADIO_NRF24
//#define MY_RADIO_NRF5_ESB
//#define MY_RADIO_RFM69
//#define MY_RADIO_RFM95
// Set LOW transmit power level as default, if you have an amplified NRF-module and
// power your radio separately with a good regulator you can turn up PA level.
#define MY_RF24_PA_LEVEL RF24_PA_LOW
// Running on Mega
#define MY_RF24_CE_PIN 49
#define MY_RF24_CS_PIN 53
#define MY_GATEWAY_MQTT_CLIENT
// Enable gateway ethernet module type
#define MY_GATEWAY_TINYGSM
// Define the GSM modem
#define TINY_GSM_MODEM_ESP8266
//#define TINY_GSM_MODEM_A6
#define MY_GSM_APN "internet"
#define MY_GSM_USR ""
#define MY_GSM_PIN ""
#define MY_GSM_PSW "E76GBLKI"
#define MY_GSM_SSID "4G-Gateway-8FAB"
// Use Hardware Serial on Mega, Leonardo, Micro
#define SerialAT Serial3
// or Software Serial on Uno, Nano
//#include <SoftwareSerial.h>
//SoftwareSerial SerialAT(2, 3); // RX, TX
// Mosquitto does not support 3.1.1, so need to use the older 3.1 version
#define MQTT_VERSION MQTT_VERSION_3_1
// Set this node's subscribe and publish topic prefix
#define MY_MQTT_PUBLISH_TOPIC_PREFIX "myGreenhouse-out"
#define MY_MQTT_SUBSCRIBE_TOPIC_PREFIX "myGreenhouse-in"
// Set MQTT client id
#define MY_MQTT_CLIENT_ID "myGreenhouse"
// Enable these if your MQTT broker requires usenrame/password
#define MY_MQTT_USER "MyGreenhouse"
#define MY_MQTT_PASSWORD "luOavOXFFFDxrQFlboaVK"
// MQTT broker ip address or url. Define one or the other.
#define MY_CONTROLLER_URL_ADDRESS "home.raitwebs.com"
// The MQTT broker port to to open
#define MY_PORT 9993
// Security and signing
#define MY_SIGNING_SOFT
#define MY_SIGNING_SOFT_RANDOMSEED_PIN 0
#define MY_SIGNING_REQUEST_SIGNATURES
// Enable inclusion mode
#define MY_INCLUSION_MODE_FEATURE
// Enable Inclusion mode button on gateway
//#define MY_INCLUSION_BUTTON_FEATURE
// Inverses behavior of inclusion button (if using external pullup)
//#define MY_INCLUSION_BUTTON_EXTERNAL_PULLUP
// Set inclusion mode duration (in seconds)
#define MY_INCLUSION_MODE_DURATION 60
// Digital pin used for inclusion mode button
//#define MY_INCLUSION_MODE_BUTTON_PIN 3
// Set blinking period
#define MY_DEFAULT_LED_BLINK_PERIOD 300
// Inverses the behavior of leds
//#define MY_WITH_LEDS_BLINKING_INVERSE
// Flash leds on rx/tx/err
// Uncomment to override default HW configurations
//#define MY_DEFAULT_ERR_LED_PIN 4 // Error led pin
//#define MY_DEFAULT_RX_LED_PIN 6 // Receive led pin
//#define MY_DEFAULT_TX_LED_PIN 5 // the PCB, on board LED
#define REPORT_INTERVAL 600 // define report interval in seconds for all sensors. This is when a full report is sent, no matter what
#define VCC_VOLTAGE_READ 5.0 // Actual supply voltage going to the VCC. Use a multimeter to check
#define VCC_VOLTAGE_REPORTED 4.97 // Set this to the same as above for your first boot. Then insert the value reported in the Serial window during boot
#define ONE_MSECOND_IN_MICROS 100 // Depends on your crystal. 8MHz crystal:500000, 16MHz crystal:1000000, etc. If your time intervals are off, this is the reason
// Air humidity and temperature sensor settings (SHT21)
#define MG_USE_AHUM
#define AHUM_MEASUREMENT_INTERVAL 10 // Time in seconds, between consecutive measurements
#define AHUM_REPORT_THRESHOLD 50 // The difference in ppm between two consecutive readings to send an immediate report
#define AHUM_HUM_ID 6
#define AHUM_TMP_ID 7
#define AHUM_DEW_ID 8
// PPM (EC) sensor settings
#define MG_USE_PPM
#define PPM_MEASUREMENT_INTERVAL 10 // Time in seconds, between consecutive measurements
#define PPM_REPORT_THRESHOLD 50 // The difference in ppm between two consecutive readings to send an immediate report
#define PPM_SENSE_PIN A13 // Analog pin used for the probe
#define PPM_POWER_PIN A8 // Digital pin used to supply power to the probe
#define PPM_GROUND_PIN A15
#define PPM_RESISTOR 560 // No less than 300 and no more than 1K resistor should be used. Around 500 gives the best resolution
#define PPM_CALIBRATION 1.00 // EC value of Calibration solution in s/cm
#define PPM_TEMP_COEF 0.019 // 0.019 is generaly considered the standard for plant nutrients [google "Temperature compensation EC" for more info]
#define PPM_EC_CONVERSION 0.64 // USA: 0.5, EU: 0.64, AU: 0.7
#define PPM_TEMP_SENSOR 10 // Temperature sensor ID that is measuring your solution temperature
#define PPM_ID 4 // MySensors Child ID
#define PPM_UNIT_ID 5 // Mysensors Child ID for selecting the unit (ms/cm or ppm)
#define PPM_CAL_ID 3 // Mysensors Child ID for the K value
// Relay settings. TODO: Make it easy to use more than two relays
#define MG_USE_RLY_1
#define MG_USE_RLY_2
#define RLY_PIN_1 5
#define RLY_PIN_2 6
#define RLY_ON 0 // GPIO value to write to turn on attached relay
#define RLY_OFF 1 // GPIO value to write to turn off attached relay
#define RLY_ID_1 1 // MySensors Child ID
#define RLY_ID_2 2 // MySensors Child ID
// LCD settings
#define LCD_BACKLIGHT_PIN 12
#define LCD_DEFAULT_CONTRAST 200
#define LCD_FONT u8g2_font_6x12_t_symbols
#define LCD_FONT_X 6
#define LCD_FONT_Y 12
#define LCD_OFFSET_X 5
#define LCD_OFFSET_Y 2
#define LCD_WIDTH 120
#define LCD_HEIGHT 60
//*********** Menu setup **********//
#define MENU_MAX_DEPTH 2
// rotary encoder pins
#define encA 3
#define encB 4
#define encBtn 2
#define ENC_STEPS_PER_NOTCH 4
#define ENC_DECODER ENC_NORMAL
//********* End Menu setup *******//
#endif // SETTINGS_H