Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

Overlapping amplicons #13

Open
aledj2 opened this issue May 10, 2020 · 1 comment
Open

Overlapping amplicons #13

aledj2 opened this issue May 10, 2020 · 1 comment

Comments

@aledj2
Copy link

aledj2 commented May 10, 2020

Hi,
I'm using an amplicon kit which has tiled amplicons. These can create super amplicons, where the forward primer for amplicon 1 can form an 'super' amplicon with the reverse primer of amplicon2.

I've created a PE bed file with one line for each of the original amplicons and another for the 'super' amplicon.

This correctly clips the outer most primers, however for the super amplicons, the right alignments are clipped at both ends (I would only expect clipping at the right). This is shown in attached screenshot, the red lines show where the softclipping starts. The tracks at the bottom show where the primers are and the lines in the paired end BED file.

image

The super amplicons provide coverage where the targets of the original amplicons do not overlap (apart from the primers) but this issue means the super amplicons are also being clipped in this gap so I am losing coverage.

This is true of every super amplicon. I've tried changing up and down to 0 and 1 to ensure reads aren't associated with a different amplicon and sorting the PE BED file so the super amplicons are first.

Is this expected behaviour? Any tips? Thanks

@donutbrew
Copy link

If these amplicons are from a multiplex PCR, it would be impossible to tell the difference from an amplicon that was generated from the outer primers only (and should not be middle trimmed) or a hybrid amplicon that is the result of two partially-overlapping precursor amplicons priming each other to become the longer amplicon.

My solution to this is to exclude longer-than-expected amplicons during the read QC step. Of course if you rely on these longer amplicons, you'll have to redesign the assay.

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment