function Get-VMDisk {
<#
.NOTES
===========================================================================
Created by: Markus Kraus
Twitter: @VMarkus_K
Private Blog: mycloudrevolution.com
===========================================================================
Changelog:
2016.09 ver 1.0 Base Release
2016.11 ver 1.1 VM pipe
2020.02 ver 1.2 Add SCSI ID
===========================================================================
External Code Sources:
http://www.lucd.info/2011/04/22/get-the-maximum-iops/
===========================================================================
Tested Against Environment:
vSphere Version: 6.7 U3
PowerCLI Version: PowerCLI 11.5
PowerShell Version: 5.1, 6.1
OS Version: Windows 2016, Windows 10
===========================================================================
Keywords vSphere, ESXi, VM, vDisk
===========================================================================
.Description
This Function reports VM vDisks and Datastores:
Get-VM MyTest | Get-VMDisk | Format-Table -AutoSize
Name PowerState Datastore Path Disk StorageFormat CapacityGB Controller Unit
---- ---------- --------- ---- ---- ------------- ---------- ---------- ----
MyTest PoweredOff data01 MyTest/MyTest.vmdk Hard disk 1 Thin 16 0 0
MyTest PoweredOff data02 MyTest/MyTest_1.vmdk Hard disk 2 Thin 20 1 0
MyTest PoweredOff data01 MyTest/MyTest_2.vmdk Hard disk 3 Thick 20 1 1
.Example
Get-VM -Name TST* | Get-VMDisk
.Example
Get-Folder -Name TST | Get-VM | Get-VMDisk | ft -AutoSize
#Requires PS -Version 5.0
#Requires -Modules VMware.VimAutomation.Core, @{ModuleName="VMware.VimAutomation.Core";ModuleVersion="6.3.0.0"}
#>
[CmdletBinding()]
param(
[Parameter(Mandatory=$True, ValueFromPipeline=$True, Position=0, HelpMessage = "VMs to process")]
[ValidateNotNullorEmpty()]
[VMware.VimAutomation.ViCore.Impl.V1.Inventory.InventoryItemImpl[]] $myVMs
)
Process {
$View = @()
foreach ($myVM in $myVMs){
$VMDKs = $myVM | get-HardDisk
foreach ($VMDK in $VMDKs) {
if ($VMDK -ne $null){
[int]$CapacityGB = $VMDK.CapacityKB/1024/1024
$Report = [PSCustomObject] @{
Name = $myVM.name
PowerState = $myVM.PowerState
Datastore = $VMDK.FileName.Split(']')[0].TrimStart('[')
Path = $VMDK.FileName.Split(']')[1].TrimStart('[')
Disk = $VMDK.Name
StorageFormat = $VMDK.StorageFormat
CapacityGB = $CapacityGB
Controller = $VMDK.ExtensionData.ControllerKey -1000
Unit = $VMDK.ExtensionData.UnitNumber
}
$View += $Report
}
}
}
$View | Sort-Object VMname, Controller, Unit
}
}