Notifications
You must be signed in to change notification settings - Fork 402
New issue
Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.
By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.
Already on GitHub? Sign in to your account
updated 'deploy-gpu-node-pool.md' with instructions for using Headless OS #3171
base: main
Are you sure you want to change the base?
Changes from 6 commits
0018650
412c583
03d48f0
0c06663
ca8cf70
8da0cdd
0557b31
b447080
File filter
Filter by extension
Conversations
Jump to
Diff view
Diff view
There are no files selected for viewing
Original file line number | Diff line number | Diff line change | ||||
---|---|---|---|---|---|---|
|
@@ -62,12 +62,37 @@ Install the Azure Stack HCI, version 23H2 operating system locally on each serve | |||||
|
||||||
### Step 2: uninstall the NVIDIA host driver | ||||||
|
||||||
On each host machine, navigate to **Control Panel > Add or Remove programs**, uninstall the NVIDIA host driver, then reboot the machine. After the machine reboots, confirm that the driver was successfully uninstalled. Open an elevated PowerShell terminal and run the following command: | ||||||
Open a remote powershell session to each host, or run the following local in Powershell. Start by uninstalling the NVIDIA host driver, then reboot the machine. After the machine reboots, confirm that the driver was successfully uninstalled: | ||||||
|
||||||
```powershell | ||||||
Get-PnpDevice | select status, class, friendlyname, instanceid | findstr /i /c:"3d video" | ||||||
PNPUTIL /enum-drivers | ||||||
``` | ||||||
|
||||||
Open an elevated PowerShell prompt and run the following command: | ||||||
|
||||||
```powershell | ||||||
Get-PnpDevice | Where-Object FriendlyName -Like '3D Video*' | Select-Object Status, FriendlyName, InstanceId | ||||||
``` | ||||||
|
||||||
You should see the installed drivers in the **PNPUTIL** output. If the **Provider Name** is listed as **NVIDIA Corporation**, that is the driver you need to target for uninstalling. Make a note of the **Published Name**, as you must use that in the next command: | ||||||
|
||||||
```output | ||||||
Published Name: oem15.inf | ||||||
Original Name: nvlwswi.inf | ||||||
Provider Name: NVIDIA | ||||||
Class Name: Display | ||||||
Class GUID: {4d36e968-e325-11ce-bfc1-08002be10318} | ||||||
Driver Version: 03/05/2024 31.0.15.5178 | ||||||
Signer Name: Microsoft Windows Hardware Compatibility Publisher | ||||||
``` | ||||||
|
||||||
Run the following command in your Powershell session, and replace `.\oem1.inf` with the value in **Published Name** from the previous **PNPUTIL Enum-Devices** output: | ||||||
|
||||||
```powershell | ||||||
pnputil /delete-driver .\oem1.inf /uninstall /reboot | ||||||
There was a problem hiding this comment. Choose a reason for hiding this commentThe reason will be displayed to describe this comment to others. Learn more. We'd better replace There was a problem hiding this comment. Choose a reason for hiding this commentThe reason will be displayed to describe this comment to others. Learn more. I call this out on line 89 and suggest that you replace the value with a value from the output. There was a problem hiding this comment. Choose a reason for hiding this commentThe reason will be displayed to describe this comment to others. Learn more. Yes. But |
||||||
``` | ||||||
After the reboot is complete, reconnect via Powershell or an RDP Session. | ||||||
|
||||||
You should see the GPU devices appear in an error state as shown in this example output: | ||||||
|
||||||
```output | ||||||
|
@@ -79,10 +104,21 @@ Error 3D Video Controller PCI\VEN_10DE&DEV_1EB8&SUBSYS_1 | |||||
|
||||||
When you uninstall the host driver, the physical GPU goes into an error state. You must dismount all the GPU devices from the host. | ||||||
|
||||||
For each GPU (3D Video Controller) device, run the following commands in PowerShell. Copy the instance ID; for example, `PCI\VEN_10DE&DEV_1EB8&SUBSYS_12A210DE&REV_A1\4&32EEF88F&0&0000` from the previous command output: | ||||||
For each GPU (3D Video Controller) device, run the following commands in PowerShell. This command will create a variable named "ID1" and "lp1" and populate the instance ID of the first GPU; for example, `PCI\VEN_10DE&DEV_1EB8&SUBSYS_12A210DE&REV_A1\4&32EEF88F&0&0000` from the previous command output. | ||||||
There was a problem hiding this comment. Choose a reason for hiding this commentThe reason will be displayed to describe this comment to others. Learn more.
Suggested change
|
||||||
|
||||||
```powershell | ||||||
$gpu=Get-PnpDevice -FriendlyName "3D Video Controller" | ||||||
$id0 =$gpu[0].InstanceId | ||||||
$lp0 = (Get-PnpDeviceProperty -KeyName DEVPKEY_Device_LocationPaths -InstanceId $id1).Data[0] | ||||||
There was a problem hiding this comment. Choose a reason for hiding this commentThe reason will be displayed to describe this comment to others. Learn more. You renamed the variables to There was a problem hiding this comment. Choose a reason for hiding this commentThe reason will be displayed to describe this comment to others. Learn more. i see the issue, quick fix. |
||||||
Disable-PnpDevice -InstanceId $id1 -Confirm:$false | ||||||
Dismount-VMHostAssignableDevice -LocationPath $lp1 -Force | ||||||
``` | ||||||
|
||||||
If you have more than one GPU, use the following additional command: | ||||||
|
||||||
```powershell | ||||||
$id1 = "<Copy and paste GPU instance id into this string>" | ||||||
$gpu=Get-PnpDevice -FriendlyName "3D Video Controller" | ||||||
$id1 =$gpu[1].InstanceId | ||||||
$lp1 = (Get-PnpDeviceProperty -KeyName DEVPKEY_Device_LocationPaths -InstanceId $id1).Data[0] | ||||||
Disable-PnpDevice -InstanceId $id1 -Confirm:$false | ||||||
Dismount-VMHostAssignableDevice -LocationPath $lp1 -Force | ||||||
|
@@ -91,7 +127,7 @@ Dismount-VMHostAssignableDevice -LocationPath $lp1 -Force | |||||
To confirm that the GPUs were correctly dismounted from the host, run the following command. You should put GPUs in an `Unknown` state: | ||||||
|
||||||
```powershell | ||||||
Get-PnpDevice | select status, class, friendlyname, instanceid | findstr /i /c:"3d video" | ||||||
Get-PnpDevice | Where-Object FriendlyName -Like '3D Video*' | Select-Object Status, FriendlyName, InstanceId | ||||||
``` | ||||||
|
||||||
```output | ||||||
|
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
Could you please move these lines (L71-76) to that between L95 and L96.