Expand Up @@ -1967,9 +1967,12 @@ If a mini-split heat pump is specified, additional information is entered in ``H
HeatingDetailedPerformanceData must also be provided.
.. [#] If HeatingDetailedPerformanceData is provided, see :ref:`htg_detailed_perf_data`.
CoolingDetailedPerformanceData must also be provided.
.. [#] | If neither extension/HeatingCapacityRetention nor HeatingCapacity17F nor HeatingDetailedPerformanceData provided, heating capacity retention defaults based on CompressorType:
| - **single/two stage**: 0.425 (at 5F)
| - **variable speed**: 0.0461 * HSPF + 0.1594 (at 5F)
.. [#] If neither extension/HeatingCapacityRetention nor HeatingCapacity17F nor HeatingDetailedPerformanceData provided, heating capacity retention defaults based on CompressorType:
\- **single/two stage**: 0.425 (at 5F)
\- **variable speed**: 0.0461 * HSPF + 0.1594 (at 5F)
.. [#] The extension/HeatingCapacityRetention input is a more flexible alternative to HeatingCapacity17F, as it can apply to autosized systems and allows the heating capacity retention to be defined at a user-specified temperature (instead of 17F).
Either input approach can be used, but not both.
.. [#] FanPowerWattsPerCFM defaults to 0.07 W/cfm for ductless systems and 0.18 W/cfm for ducted systems.