Skip to content

MAX31855: fix sign of readReferenceTemperature function #17

New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

Merged
merged 2 commits into from
Jun 21, 2024
Merged
Changes from all commits
Commits
File filter

Filter by extension

Filter by extension

Conversations
Failed to load comments.
Loading
Jump to
Jump to file
Failed to load files.
Loading
Diff view
Diff view
4 changes: 2 additions & 2 deletions src/utility/THERMOCOUPLE/MAX31855.cpp
Original file line number Diff line number Diff line change
Expand Up @@ -208,15 +208,15 @@ float MAX31855Class::readReferenceTemperature(int type)

// The cold junction reference temperature is stored in the first 11 word's bits
// sent by the Thermocouple-to-Digital Converter
rawword = rawword & 0x7FF;
rawword = rawword & 0xFFF;
// check sign bit and convert to negative value.
if (rawword & 0x800) {
ref = (0xF800 | (rawword & 0x7FF))*0.0625;
} else {
// multiply for the LSB value
ref = rawword * 0.0625f;
}
Serial.println(ref);

return ref;
}

Expand Down
Loading