Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

Update README.md - quick typo fix #428

Open
wants to merge 2 commits into
base: master
Choose a base branch
from
Open
Changes from all commits
Commits
File filter

Filter by extension

Filter by extension

Conversations
Failed to load comments.
Loading
Jump to
Jump to file
Failed to load files.
Loading
Diff view
Diff view
12 changes: 8 additions & 4 deletions README.md
Original file line number Diff line number Diff line change
Expand Up @@ -2,7 +2,7 @@

# Control Beta Test

This repo includes a beta version of device control using the same API as the SolisCloud app. This opeartes slighty differently depending on your HMI firmware version. This should be detected automatically.
This repo includes a beta version of device control using the same API as the SolisCloud app. This operates slighty differently depending on your HMI firmware version. This should be detected automatically.

Please report any issues via https://github.com/fboundy/solis-sensor/issues

Expand All @@ -15,7 +15,8 @@ The following controls should update the inverter immediately:
- Force Charge SOC
- Backup SOC

The timed change controls are all sent to the API using one command and so they won't update untill the Update Charge/Discharge button is pressed. The controls included in this are all three sets of the following (where N is slots 1-3)
The timed change controls are all sent to the API using one command and so they won't update untill the Update Charge/Discharge button is pressed. The controls included in this are all three sets of the following (where N is slots 1-3):

- Timed Charge Current N
- Timed Charge Start Time N
- Timed Charge End Time N
Expand All @@ -27,7 +28,8 @@ The timed change controls are all sent to the API using one command and so they

## Version 4B00 and Later

Six slots are available and include an SOC limit and a voltage (though the purpose of the voltage is not clear). Only the start and end times for each Charge/Discharge slot need top to be sent to the inverter together so the following are updated immediately (where N is slot 1-6):
Six slots are available and include an SOC limit and a voltage (though the purpose of the voltage is not clear). Only the start and end times for each Charge/Discharge slot need to to be sent to the inverter together so the following are updated immediately (where N is slot 1-6):

- Energy Storage Control Switch (fewer available modes than pre-4B00)
- Overdischarge SOC
- Force Charge SOC
Expand All @@ -39,18 +41,20 @@ Six slots are available and include an SOC limit and a voltage (though the purpo
- Timed Discharge SOC N
- Timed Discharge Voltage N

Each pair of start/end times has an associated button pushfor charge there are 6:
Each pair of start/end times has an associated button push; for charge (where N is slot 1-6):

- Timed Charge Start Time N
- Timed Charge End Time N
- Button Update Charge Time N

And discharge:

- Timed Discharge Start Time N
- Timed Discharge End Time N
- Button Update Discharge Time N