Skip to content

Commit

Permalink
Merge branch 'master' into cstation/rail3
Browse files Browse the repository at this point in the history
  • Loading branch information
naveedkhan8067 authored Jan 17, 2025
2 parents 8b19a85 + 171dcdd commit fd4308d
Show file tree
Hide file tree
Showing 3 changed files with 23 additions and 11 deletions.
Original file line number Diff line number Diff line change
Expand Up @@ -32,4 +32,8 @@
<KindOfQuantity typeName="PERCENTAGE" displayLabel="Road &amp; Rail Percentage" persistenceUnit="u:DECIMAL_PERCENT" presentationUnits="f:DefaultRealU(2)[u:PERCENT];f:DefaultRealU(4)[u:DECIMAL_PERCENT]" relativeError="0.0001"/>
<KindOfQuantity typeName="SIDE_SLOPE" displayLabel="Road &amp; Rail Side Slope" persistenceUnit="u:M_HORIZONTAL_PER_M_VERTICAL" presentationUnits="f:DefaultRealU(1)[u:HORIZONTAL_PER_VERTICAL]" relativeError="0.0001"/>
<KindOfQuantity typeName="INTENSITY_INFILTRATION" displayLabel="Road &amp; Rail Intensity/Infiltration" persistenceUnit="u:M_PER_SEC" presentationUnits="f:DefaultRealU(2)[u:MM_PER_HR];f:DefaultRealU(2)[u:IN_PER_HR]" relativeError="0.0001"/>
</ECSchema>
<KindOfQuantity typeName="RATIONAL_COEFFICIENT" displayLabel="Road &amp; Rail Rational Coefficient" persistenceUnit="u:COEFFICIENT" presentationUnits="f:DefaultRealU(2)[u:COEFFICIENT]" relativeError="0.0001"/>
<KindOfQuantity typeName="MANNINGS_N" displayLabel="Road &amp; Rail Manning's n" persistenceUnit="u:COEFFICIENT" presentationUnits="f:DefaultRealU(3)[u:COEFFICIENT]" relativeError="0.0001"/>
<KindOfQuantity typeName="HAZEN_WILLIAMS_C" displayLabel="Road &amp; Rail Hazen-William's C" persistenceUnit="u:COEFFICIENT" presentationUnits="f:DefaultRealU(0)[u:COEFFICIENT]" relativeError="0.0001"/>

</ECSchema>
Original file line number Diff line number Diff line change
Expand Up @@ -10,7 +10,7 @@
<ECSchemaReference name="BisCore" version="01.00.10" alias="bis" />
<ECSchemaReference name="Analytical" version="01.00.01" alias="anlyt" />
<ECSchemaReference name="AecUnits" version="01.00.03" alias="AECU"/>
<ECSchemaReference name="RoadRailUnits" version="01.00.02" alias="rru"/>
<ECSchemaReference name="RoadRailUnits" version="01.00.03" alias="rru"/>
<ECSchemaReference name="PipeworkPhysical" version="01.00.01" alias="pipphys"/>

<ECCustomAttributes>
Expand Down Expand Up @@ -39,9 +39,9 @@

<ECEntityClass typeName="HydraulicMaterialAspect" modifier="Sealed" displayLabel="Hydraulic Material Aspect">
<BaseClass >bis:ElementUniqueAspect</BaseClass>
<ECProperty propertyName="ManningsN" typeName="double" displayLabel="Manning's n"/>
<ECProperty propertyName="KuttersN" typeName="double" displayLabel="Kutter's n"/>
<ECProperty propertyName="HazenWilliamsC" typeName="double" displayLabel="Hazen-William's C"/>
<ECProperty propertyName="ManningsN" typeName="double" kindOfQuantity="rru:MANNINGS_N" displayLabel="Manning's n"/>
<ECProperty propertyName="KuttersN" typeName="double" kindOfQuantity="rru:MANNINGS_N" displayLabel="Kutter's n"/>
<ECProperty propertyName="HazenWilliamsC" typeName="double" kindOfQuantity="rru:HAZEN_WILLIAMS_C" displayLabel="Hazen-William's C"/>
<ECProperty propertyName="DarcyWeisbachRoughnessHeight" typeName="double" kindOfQuantity="rru:LENGTH_SHORT" displayLabel="Darcy-Weisbach Roughness Height"/>
</ECEntityClass>

Expand Down
Original file line number Diff line number Diff line change
Expand Up @@ -13,6 +13,7 @@
<ECSchemaReference name="RoadRailUnits" version="01.00.03" alias="rru"/>
<ECSchemaReference name="NetworkTopology" version="01.00.01" alias="net"/>
<ECSchemaReference name="StormSewerPhysical" version="01.00.01" alias="stmswrphys"/>
<ECSchemaReference name="SchemaUpgradeCustomAttributes" version="01.00.00" alias="SchemaUpgradeCA"/>

<ECCustomAttributes>
<ProductionStatus xmlns="CoreCustomAttributes.01.00.03">
Expand Down Expand Up @@ -845,7 +846,7 @@
<BaseClass>net:IEdge</BaseClass>
<ECProperty propertyName="StartInvert" typeName="double" displayLabel="Invert (Start)" category="HydraulicData" kindOfQuantity="rru:ELEVATION" description="Set the invert of pipe adjacent to the start node."/>
<ECProperty propertyName="StopInvert" typeName="double" displayLabel="Invert (Stop)" category="HydraulicData" kindOfQuantity="rru:ELEVATION" description="Set the invert of the pipe adjacent to the stop node."/>
<ECProperty propertyName="ManningsN" typeName="double" displayLabel="Manning's n" category="HydraulicData" description="The roughness value for the pipe."/>
<ECProperty propertyName="ManningsN" typeName="double" displayLabel="Manning's n" kindOfQuantity="rru:MANNINGS_N" category="HydraulicData" description="The roughness value for the pipe."/>
<ECProperty propertyName="PlanLength" typeName="double" displayLabel="Length" category="HydraulicData" kindOfQuantity="rru:LENGTH" description="The horizontal length of the pipe."/>
</ECEntityClass>

Expand Down Expand Up @@ -1019,7 +1020,14 @@

<ECEntityClass typeName="CatchmentRationalSimpleAreaAspect" modifier="Sealed" displayLabel="CatchmentRationalSimpleAreaAspect">
<BaseClass >CatchmentSimpleAreaDefinitionAspect</BaseClass>
<ECProperty propertyName="RationalC" typeName="double" displayLabel="Rational C" category="HydraulicData" kindOfQuantity="rru:PERCENTAGE" description="The runoff coefficient used with the Rational Method. C in Q=CiA."/>
<ECProperty propertyName="RationalC" typeName="double" displayLabel="Rational C" category="HydraulicData" kindOfQuantity="rru:RATIONAL_COEFFICIENT" description="The runoff coefficient used with the Rational Method. C in Q=CiA.">
<ECCustomAttributes>
<AllowUnitChange xmlns="SchemaUpgradeCustomAttributes.01.00.00">
<From>u:DECIMAL_PERCENT</From>
<To>u:COEFFICIENT</To>
</AllowUnitChange>
</ECCustomAttributes>
</ECProperty>
</ECEntityClass>

<ECEntityClass typeName="CatchmentRationalComplexAreaDefinitionAspect" modifier="Sealed" displayLabel="CatchmentRationalComplexAreaAspect">
Expand All @@ -1029,16 +1037,16 @@

<ECStructClass typeName="RationalSubarea" modifier="Sealed" description="The list of subareas that comprise the total area of the catchment. The weighted average of the rational c value will be used to compute the runoff.">
<ECProperty propertyName="RationalSubareaArea" typeName="double" displayLabel="Area" category="HydraulicData" kindOfQuantity="rru:AREA" description="The size of the subarea."/>
<ECProperty propertyName="RationalSubareaC" typeName="double" displayLabel="Rational C" category="HydraulicData" description="The Rational C coefficient to be applied to the current subarea."/>
<ECProperty propertyName="RationalSubareaC" typeName="double" displayLabel="Rational C" category="HydraulicData" kindOfQuantity="rru:RATIONAL_COEFFICIENT" description="The Rational C coefficient to be applied to the current subarea."/>
</ECStructClass>

<ECEntityClass typeName="EpaSWMMRunoffMethodAreaAspect" modifier="Sealed" displayLabel="EPA SWMM Runoff Method">
<BaseClass >CatchmentSimpleAreaDefinitionAspect</BaseClass>
<ECProperty propertyName="CharacteristicWidth" typeName="double" displayLabel="Characteristic Width" category="HydraulicData" description="The width of the overland flow path for sheet flow runoff (note: the catchment area occupied by Low Impact Development Controls (if any) should not be considered when determining characteristic width)." kindOfQuantity="rru:LENGTH" />
<ECProperty propertyName="CatchmentSlope" typeName="double" displayLabel="Slope (Catchment)" category="HydraulicData" kindOfQuantity="rru:SLOPE" description="Average slope of the catchment."/>
<ECProperty propertyName="ManningsNImpervious" typeName="double" displayLabel="Manning's n (Impervious)" category="HydraulicData" description="Manning's n for overland flow over the impervious portion of the catchment."/>
<ECProperty propertyName="ManningsNPervious" typeName="double" displayLabel="Manning's n (Pervious)" category="HydraulicData" description="Manning's n for overland flow over the pervious portion of the catchment."/>
<ECProperty propertyName="DepressionStorageImpervious" typeName="double" displayLabel="Storage (Impervious Depression)" category="HydraulicData" kindOfQuantity="rru:LENGTH_SHORT" description="Manning's n for overland flow over the pervious portion of the catchment."/>
<ECProperty propertyName="ManningsNImpervious" typeName="double" displayLabel="Manning's n (Impervious)" category="HydraulicData" kindOfQuantity="rru:MANNINGS_N" description="Manning's n for overland flow over the impervious portion of the catchment."/>
<ECProperty propertyName="ManningsNPervious" typeName="double" displayLabel="Manning's n (Pervious)" category="HydraulicData" kindOfQuantity="rru:MANNINGS_N" description="Manning's n for overland flow over the pervious portion of the catchment."/>
<ECProperty propertyName="DepressionStorageImpervious" typeName="double" displayLabel="Storage (Impervious Depression)" category="HydraulicData" kindOfQuantity="rru:LENGTH_SHORT" description="Depth of depression storage on the impervious portion of the catchment."/>
<ECProperty propertyName="DepressionStoragePervious" typeName="double" displayLabel="Storage (Pervious Depression)" category="HydraulicData" kindOfQuantity="rru:LENGTH_SHORT" description="Depth of depression storage on the pervious portion of the catchment."/>
<ECProperty propertyName="PercentImpervious" typeName="double" displayLabel="Percent Impervious" category="HydraulicData" kindOfQuantity="rru:PERCENTAGE" description="Percent of land area (not including any land in this catchment associated with a Low Impact Development Control) that is impervious."/>
<ECProperty propertyName="PercentZeroStorageImpervious" typeName="double" displayLabel="Percent Zero Storage on Impervious" category="HydraulicData" kindOfQuantity="rru:PERCENTAGE" description="Percent of the impervious area with no depression storage."/>
Expand Down

0 comments on commit fd4308d