Skip to content

Add missing configuration to ConfigureUCLAMiniscopeV4Camera#403

Merged
bparks13 merged 2 commits intomainfrom
issue-402
Jan 17, 2025
Merged

Add missing configuration to ConfigureUCLAMiniscopeV4Camera#403
bparks13 merged 2 commits intomainfrom
issue-402

Conversation

@jonnew
Copy link
Member

@jonnew jonnew commented Jan 17, 2025

  • The ConfigureUCLAMiniscopeV4Camera passthrough configuration assumed that passthrough device registers were defaulted prior to configuring the device to receive miniscope data. If the passthrough device was used for something else (e.g. neuropixels headstage) before this, then this would not be the case. Now we explicitly set all passthrough registers in ConfigureUCLAMiniscopeV4Camera to the correct values.
  • Fixes Miniscope not sending camera data, but can be controlled and IMU sensor data acquired #402

- The ConfigureUCLAMiniscopeV4Camera passthrough configuration
  assumed that passthrough device registers were defaulted prior
  to configuring the device to receive miniscope data. If the
  passthrough device was used for something else
  (e.g. neuropixels headstage) before this, then this would not
  be the case. Now we explicitly set all passthrough registers in
  ConfigureUCLAMiniscopeV4Camera to the correct values.
@jonnew jonnew requested review from aacuevas and bparks13 January 17, 2025 18:41
Copy link
Collaborator

@aacuevas aacuevas left a comment

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

DS90UB9x.MAGIC should be also set to 0 for safety. Apart from that, seems good.

- This was missing in the previous commit
@jonnew
Copy link
Member Author

jonnew commented Jan 17, 2025

Oops, should be good now. @bparks13 I think this is ready

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment

Labels

None yet

Projects

None yet

Development

Successfully merging this pull request may close these issues.

Miniscope not sending camera data, but can be controlled and IMU sensor data acquired

3 participants