Exclude the first 10 seconds of measurement
x<10
Only use the first 50 seconds of measurement
t>50
The choice of variable is irrelevant (except for N or n which have a special meaning. see below)
a<10
is the same as
b<10
Use only the first 100 points
100
Exclude the first 20 points. (NOTE: the use of N or n tells pychron to truncate by the point number not its time since time-zero)
n<=20